Loss of or Accidental Electrical Closure of the Bleed Pressure-Regulator Valve of the Engine 2
TASK 36-11-00-810-864-A
Loss of or Accidental Electrical Closure of the Bleed Pressure-Regulator Valve of the Engine 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-176-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-865-060-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:46 UTC
Loss of or Accidental Electrical Closure of the Bleed Pressure-Regulator Valve of the Engine 2
1. Possible Causes
- wiring
- SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2]
- P/BSW-ENG 2 BLEED [4HA2]
- C/B-AIR BLEED/ENG 2/CTL [3HA2]
- BMC-2 [1HA2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| AMM 36-11-00-740-001 | BITE Test of the BMC 1(2) |
| ASM 361102 | |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| AMM 36-11-55-000-001 | Removal of the Bleed-Pressure-Regulator Valve Control-Solenoid |
| AMM 36-11-55-400-001 | Installation of the Bleed-Pressure-Regulator Valve Control-Solenoid |
Subtask 36-11-00-710-176-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-865-060-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 36-11-00-810-114-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
B. If the test gives the maintenance message:
BMC2 or SOLENOID 10HA2 CKT
Subtask 36-11-00-810-114-B ** ON A/C NOT FOR ALL BMC2 or SOLENOID 10HA2 CKT
- do a check of the status of the circuit breaker (3HA2).
- do a check for 28VDC at pin A/1 of the connector of the bleed pressure-regulator valve control-solenoid (10HA2) with the ENG 2 BLEED pushbutton switch (4HA2) released (OFF legend on).
- do a check for ground at pin A/2 of the connector of the bleed pressure-regulator valve control-solenoid (10HA2).
- repair the wiring from the pin A/2 to the ground point.
- replace the SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- do a check for 28VDC at pin A/D2 of the ENG 2 BLEED pushbutton switch (4HA2).
- replace the P/BSW-ENG 2 BLEED [4HA2] .
- do a check and repair the wiring from the bleed pressure-regulator valve control-solenoid to the ENG 2 BLEED pushbutton switch, pin A/1 to pin A/D3.
- do a check and repair the wiring from the ENG 2 BLEED pushbutton switch pin A/D2 to the circuit breaker 3HA2 pin 2.
- replace the C/B-AIR BLEED/ENG 2/CTL [3HA2] .
- do the procedure (Ref. TSM TASK 24-00-00-810-803).
- remove the BMC-2 [1HA2] AMM 36-11-34-000-001,
- do a check for 28VDC at pin AA/8A of the BMC2.
- do a check and repair the wiring from the BMC2 pin AA/8A to the circuit breaker 3HA2 pin 2.
- do a check of the wiring between pin A/D1 of the ENG 2 BLEED pushbutton switch and pin AA/7A of the BMC2.
- replace the P/BSW-ENG 2 BLEED [4HA2] .
- Replace the BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- repair the wiring between pin A/D1 of the ENG 2 BLEED pushbutton switch and pin AA/7A of the BMC2 ASM 361102.
B. If the test gives the maintenance message:
BMC2 OR SOLENOID 10HA2 CKT
Subtask 36-11-00-710-177-A ** ON A/C NOT FOR ALL BMC2 OR SOLENOID 10HA2 CKT
NOTE: If the maintenance message BMC2 OR SOLENOID 10HA2 CKT comes into view with no associated ECAM warning, no trouble shooting procedure is necessary.
- Do a check of the status of the circuit breaker (3HA2).
- Do a check for 28 VDC at pin A/1 of the connector of the bleed pressure regulator valve control solenoid (10HA2) with the ENG 2 BLEED pushbutton switch (4HA2) released (OFF legend on).
- Do a check for ground at pin A/2 of the connector of the bleed pressure-regulator valve control-solenoid (10HA2).
- Repair the wiring from the pin A/2 to the ground point.
- Replace the SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- Do a check for 28 VDC at pin A/D2 of the ENG 2 BLEED pushbutton switch (4HA2).
- Replace the P/BSW-ENG 2 BLEED [4HA2] .
- Do a check and repair the wiring from the pin A/1 of the bleed pressure regulator valve control solenoid to the pin A/D3 of the ENG 2 BLEED pushbutton switch.
- Do a check and repair the wiring from the pin A/D2 of the ENG 2 BLEED pushbutton switch to the pin 2 of the circuit breaker 3HA2.
- Replace the C/B-AIR BLEED/ENG 2/CTL [3HA2] .
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Remove the BMC-2 [1HA2] AMM 36-11-34-000-001.
- Do a check for 28 VDC at pin AA/8A of the BMC2.
- Do a check and repair the wiring from the BMC2 pin AA/8A to the circuit breaker 3HA2 pin 2.
- Do a check of the wiring between pin A/D1 of the ENG 2 BLEED pushbutton switch and pin AA/7A of the BMC2.
- Replace the P/BSW-ENG 2 BLEED [4HA2] .
- Replace the BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- Repair the wiring between pin A/D1 of the ENG 2 BLEED pushbutton switch and pin AA/7A of the BMC2 ASM 361102.
C. Do the test given in Para. 3.