Failure of the Bleed Air Precooler-Exchanger of the Engine 2


TASK 36-11-00-810-862-A
Failure of the Bleed Air Precooler-Exchanger of the Engine 2


1. Possible Causes
  • EXCHANGER-BLEED AIR PRECOOL [7150HM2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-42-000-001
Removal of the Bleed-Air Precooler Exchanger
AMM 36-11-42-400-001
Installation of the Bleed-Air Precooler Exchanger
3. Fault Confirmation
Subtask 36-11-00-710-168-A ** ON A/C NOT FOR ALL
A. Test
   (1) Not Applicable
4. Fault Isolation
Subtask 36-11-00-810-110-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message:
PRECOOLER
   (1) If the fault continues:
  • do a check and repair the clogged duct between the fan of the engine and the fan air valve (9HA2).
Subtask 36-11-00-710-169-A ** ON A/C NOT FOR ALL
B. Test
   (1) Do the engine start procedure.
   (2) Make sure that the ECAM warning AIR ENG 2 BLEED FAULT is not shown on the upper ECAM DU.