Loss of the Bus from the EIU2
TASK 36-11-00-810-856-A
Loss of the Bus from the EIU2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-156-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-810-104-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:45 UTC
Loss of the Bus from the EIU2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-00-740-001 | BITE Test of the BMC 1(2) |
| ASM 361103 | |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| AMM 73-25-34-000-040 | Removal of the Engine Interface Unit (EIU) |
| AMM 73-25-34-400-040 | Installation of the Engine Interface Unit (EIU) |
Subtask 36-11-00-710-156-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-810-104-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
NO DATA FROM EIU
Subtask 36-11-00-810-104-C ** ON A/C NOT FOR ALL NO DATA FROM EIU
- replace the BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- do a check and repair the wiring of the VALVE CLOSURE FOR ENGINE START signal from the BMC2 (1HA2) to the EIU2 (1KS2), pins AA/7C and AA/8C to pins AB/5H and AB/5K ASM 361103.
- replace the EIU-2 [1KS2] AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
A. If the BITE test gives the maintenance message:
NO DATA FROM EIU2
Subtask 36-11-00-710-157-A ** ON A/C NOT FOR ALL NO DATA FROM EIU2
- replace the BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- do a check of the wiring ASM 361103 between:
. pin AA/7C of the BMC2 (1HA2) and pin AB/5H of the EIU2 (1KS2)
. pin AA/8C of the BMC2 and pin AB/5K of the EIU2.
- repair the wiring.
- replace the EIU-2 [1KS2] AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
B. Do the test given in Para. 3.