W DOC AIRBUS | TSM A320F

Loss of the Bus from the EIU2


TASK 36-11-00-810-856-A
Loss of the Bus from the EIU2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
ASM 361103
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
AMM 73-25-34-000-040
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-040
Installation of the Engine Interface Unit (EIU)
3. Fault Confirmation
Subtask 36-11-00-710-156-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the BMC2 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-11-00-810-104-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
NO DATA FROM EIU
   (1) If the fault continues:
  • do a check and repair the wiring of the VALVE CLOSURE FOR ENGINE START signal from the BMC2 (1HA2) to the EIU2 (1KS2), pins AA/7C and AA/8C to pins AB/5H and AB/5K ASM 361103.
   (2) If the fault continues:
Subtask 36-11-00-810-104-C ** ON A/C NOT FOR ALL
A. If the BITE test gives the maintenance message:
NO DATA FROM EIU2
   (1) If the fault continues:
  • do a check of the wiring ASM 361103 between:
    . pin AA/7C of the BMC2 (1HA2) and pin AB/5H of the EIU2 (1KS2)
    . pin AA/8C of the BMC2 and pin AB/5K of the EIU2.
     (a) If the wiring is not correct:
  • repair the wiring.
     (b) If the wiring is correct:
Subtask 36-11-00-710-157-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:45 UTC