Fan Air Valve of the Engine 2 Blocked in the Open Position
TASK 36-11-00-810-850-A
Fan Air Valve of the Engine 2 Blocked in the Open Position
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-144-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-810-098-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:45 UTC
Fan Air Valve of the Engine 2 Blocked in the Open Position
1. Possible Causes
- THERMOSTAT-FAN AIR VALVE CTL [7170HM]
- SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2]
- VALVE-FAN AIR, ENG2 [9HA2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-17-000-001 | Removal of the Heat-Exchanger Outlet-Temperature Sensor |
| AMM 36-11-17-400-001 | Installation of the Heat-Exchanger Outlet-Temperature Sensor |
| AMM 36-11-43-000-001 | Removal of the Fan-Air Valve Control-Thermostat |
| AMM 36-11-43-400-001 | Installation of the Fan-Air Valve Control-Thermostat |
| AMM 36-11-54-000-001 | Removal of the Fan Air Valve |
| AMM 36-11-54-400-001 | Installation of the Fan Air Valve |
Subtask 36-11-00-710-144-A ** ON A/C NOT FOR ALL
A. Test
(1) Not applicable.
4. Fault Isolation(1) Not applicable.
Subtask 36-11-00-810-098-B ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message:
FAN AIR V 9HA2 OR THRM CTL 7170HM2
(1) Replace the THERMOSTAT-FAN AIR VALVE CTL [7170HM] AMM 36-11-43-000-001 and AMM 36-11-43-400-001.
(2) If the fault continues:
Subtask 36-11-00-810-098-C ** ON A/C NOT FOR ALL FAN AIR V 9HA2 OR THRM CTL 7170HM2
(1) Replace the THERMOSTAT-FAN AIR VALVE CTL [7170HM] AMM 36-11-43-000-001 and AMM 36-11-43-400-001.
(2) If the fault continues:
- on the AIR control panel 30VU, with the APU BLEED pushbutton switch pushed and the X-BLEED selector switch set to OPEN, do a check on the ECAM BLEED page, of the temperature indication of the two systems.
- replace the SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2] AMM 36-11-17-000-001 and AMM 36-11-17-400-001.
- replace the VALVE-FAN AIR, ENG2 [9HA2] AMM 36-11-54-000-001 and AMM 36-11-54-400-001.
A. If the fault symptom is identified by the maintenance message:
THRM 7170HM2 OR FAN AIR-V 9HA2
Subtask 36-11-00-710-145-A ** ON A/C NOT FOR ALL THRM 7170HM2 OR FAN AIR-V 9HA2
- replace the THERMOSTAT-FAN AIR VALVE CTL [7170HM] AMM 36-11-43-000-001 and AMM 36-11-43-400-001.
- on the AIR COND panel 30VU, with the APU BLEED pushbutton switch pushed and the X-BLEED selector switch set to OPEN, do a check of the temperature indication of the two systems on the ECAM BLEED page.
- replace the SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2] AMM 36-11-17-000-001 and AMM 36-11-17-400-001.
- replace the VALVE-FAN AIR, ENG2 [9HA2] AMM 36-11-54-000-001 and AMM 36-11-54-400-001.
B. After the subsequent flight, make sure that the fault does not continue.