Fan Air Valve of the Engine 2 Not in Fully Open Position
TASK 36-11-00-810-848-A
Fan Air Valve of the Engine 2 Not in Fully Open Position
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-140-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:45 UTC
Fan Air Valve of the Engine 2 Not in Fully Open Position
1. Possible Causes
- THERMOSTAT-FAN AIR VALVE CTL [7170HM]
- VALVE-FAN AIR, ENG2 [9HA2]
sense line between the fan-air valve control-thermostat (7170HM) and the fan air valve (9HA2) - SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2]
- wiring
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CAP - BLANKING |
| No specific | Torque wrench: range to between 1.76 and 1.44 m.daN (12.98 and 10.62 lbf.ft ) ![]() | |
| 98L36103002000 | 1 | TEST SET - ENGINE BLEED |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-00-710-003 | Operational Test of the Bleed Air System |
| ASM 361102 | |
| AMM 36-11-17-000-001 | Removal of the Heat-Exchanger Outlet-Temperature Sensor |
| AMM 36-11-17-400-001 | Installation of the Heat-Exchanger Outlet-Temperature Sensor |
| AMM 36-11-43-000-001 | Removal of the Fan-Air Valve Control-Thermostat |
| AMM 36-11-43-000-003 | Removal of the Filter of the Fan-Air Valve Control-Thermostat |
| AMM 36-11-43-400-001 | Installation of the Fan-Air Valve Control-Thermostat |
| AMM 36-11-43-400-003 | Installation of the Filter of the Fan-Air Valve Control-Thermostat |
| AMM 36-11-49-000-029 | Removal of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-49-000-820 | Removal of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-49-400-029 | Installation of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-49-400-820 | Installation of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-54-000-001 | Removal of the Fan Air Valve |
| AMM 36-11-54-400-001 | Installation of the Fan Air Valve |
| AMM 36-11-54-720-001 | Functional Test of the Opening of the Fan Air Valve 9HA1 with the Bleed Test Set P/N 98D36003000000 |
Subtask 36-11-00-710-140-A ** ON A/C NOT FOR ALL
A. Not applicable.
4. Fault IsolationCAUTION:
BE CAREFUL WITH THE SEMI-FLEXIBLE SENSE LINE. DEFORMATION OF THE RIGID PART OR LARGE DEFORMATION OF THE FLEXIBLE PART CAN QUICKLY CAUSE LEAKAGE.
CAUTION:
USE TWO WRENCHES DURING DISCONNECTION OF THE SENSE LINE, ONE TO MAINTAIN THE FIXED NUT AND THE SECOND ONE TO LOOSEN/TIGHTEN THE SENSE LINE COUPLING.
NOTE: For the test of the engine bleed-air system, Airbus recommends to use bleed test set P/N 98L36103002000 for more accuracy.
Subtask 36-11-00-810-096-I ** ON A/C NOT FOR ALL A. If the fault symptom is identified by the maintenance message
FAN AIR V 9HA2 or THRM 7170HM2 or SENSE LINE:
(2) If the unions are correctly tightened:
Subtask 36-11-00-810-096-K ** ON A/C NOT FOR ALL FAN AIR V 9HA2 or THRM 7170HM2 or SENSE LINE:
- Do a check of the the unions and clamps of the sense line between the fan-air valve control-thermostat (7170HM) and the fan air valve (9HA2).
(2) If the unions are correctly tightened:
- Do a check of the filter of the fan-air valve control-thermostat (7170HM).
- Clean the THERMOSTAT-FAN AIR VALVE CTL [7170HM] in the overhaul facility or replace it with a new or a clean one AMM 36-11-43-000-003 and AMM 36-11-43-400-003.
- Do the functional test of the opening of the fan air valve AMM 36-11-54-720-001.
- Replace the VALVE-FAN AIR, ENG2 [9HA2] AMM 36-11-54-000-001 and AMM 36-11-54-400-001.
- Disconnect the sense line from the fan-air valve control-thermostat (7170HM).
- Put a CAP - BLANKING on the union of the sense line of the fan-air valve control-thermostat.
- Connect a 98L36103002000 TEST SET - ENGINE BLEED to the sense line from the fan air valve.
NOTE: For more accuracy you can use the tools that follow in this order:
- Pressurize the sense line to 2.07 bar (30 psi), then close the shutoff valve of the pressure source.
- Repair or replace the
sense line between the fan-air valve control-thermostat (7170HM) and the fan air valve (9HA2) AMM 36-11-49-000-029 and AMM 36-11-49-400-029.
- Replace the THERMOSTAT-FAN AIR VALVE CTL [7170HM] AMM 36-11-43-000-001 and AMM 36-11-43-400-001.
* If the fault continues:
* - Replace the SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2] AMM 36-11-17-000-001 and AMM 36-11-17-400-001.
- Do a check of the wiring ASM 361102 between:
. Pin A/1 of the fan air valve (9HA2) and pin AA/12A of the BMC2 (1HA2)
. Pin A/3 of the fan air valve and the ground terminal.
- Repair the wiring.
- Replace the VALVE-FAN AIR, ENG2 [9HA2] AMM 36-11-54-000-001 and AMM 36-11-54-400-001.
A. If the fault symptom is identified by the maintenance message
THRM 7170HM2 OR FAN AIR VALVE 9HA2 OR SENSE LINE:
(2) If the unions are correctly tightened:
Subtask 36-11-00-810-096-L ** ON A/C NOT FOR ALL THRM 7170HM2 OR FAN AIR VALVE 9HA2 OR SENSE LINE:
- Do a check of the unions and the clamps of the sense line between the fan-air valve control-thermostat (7170HM) and the fan air valve (9HA2).
(2) If the unions are correctly tightened:
- Do a check of the filter of the fan air valve control thermostat (7170HM).
- Clean the THERMOSTAT-FAN AIR VALVE CTL [7170HM] in the overhaul facility or replace it with a new or a clean one AMM 36-11-43-000-003 and AMM 36-11-43-400-003.
- Do the functional test of the opening of the fan air valve AMM 36-11-54-720-001.
- Replace the VALVE-FAN AIR, ENG2 [9HA2] AMM 36-11-54-000-001 and AMM 36-11-54-400-001.
- Disconnect the sense line from the fan air valve control thermostat (7170HM).
- Put a CAP - BLANKING on the union of the sense line of the fan-air valve control-thermostat.
- Connect a 98L36103002000 TEST SET - ENGINE BLEED to the sense line from the fan air valve.
NOTE: For more accuracy you can use the tools that follow in this order:
- Pressurize the sense line to 2.1 bar (30 psi), then close the shutoff valve of the pressure source.
- Repair or replace the
sense line between the fan-air valve control-thermostat (7170HM) and the fan air valve (9HA2) AMM 36-11-49-000-029 and AMM 36-11-49-400-029.
- Replace the THERMOSTAT-FAN AIR VALVE CTL [7170HM] AMM 36-11-43-000-001 and AMM 36-11-43-400-001.
* If the fault continues:
* - Replace the SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2] AMM 36-11-17-000-001 and AMM 36-11-17-400-001.
- Do a check of the wiring ASM 361102 between:
. Pin A/1 of the fan air valve (9HA2) and pin AA/12A of the BMC2 (1HA2)
. Pin A/3 of the fan air valve and the ground terminal.
- Repair the wiring.
- Replace the VALVE-FAN AIR, ENG2 [9HA2] AMM 36-11-54-000-001 and AMM 36-11-54-400-001.
A. If the fault symptom is identified by the maintenance message
THRM 7170HM2 OR FAN AIR VALVE 9HA2 OR SENSE LINE:
(2) If the unions are correctly tightened:
Subtask 36-11-00-710-141-A ** ON A/C NOT FOR ALL THRM 7170HM2 OR FAN AIR VALVE 9HA2 OR SENSE LINE:
- Do a check of the unions and the clamps of the sense line between the fan-air valve control-thermostat (7170HM) and the fan air valve (9HA2).
(2) If the unions are correctly tightened:
- Do a check of the filter of the fan air valve control thermostat (7170HM).
- Clean the THERMOSTAT-FAN AIR VALVE CTL [7170HM] in the overhaul facility or replace it with a new or a clean one AMM 36-11-43-000-003 and AMM 36-11-43-400-003.
- Do the functional test of the opening of the fan air valve AMM 36-11-54-720-001.
- Replace the VALVE-FAN AIR, ENG2 [9HA2] AMM 36-11-54-000-001 and AMM 36-11-54-400-001.
- Disconnect the sense line from the fan air valve control thermostat (7170HM).
- Put a CAP - BLANKING on the union of the sense line of the fan-air valve control-thermostat.
- Connect a 98L36103002000 TEST SET - ENGINE BLEED to the sense line from the fan air valve.
NOTE: For more accuracy you can use the tools that follow in this order:
- Pressurize the sense line to 2.1 bar (30 psi), then close the shutoff valve of the pressure source.
- Repair or replace the
sense line between the fan-air valve control-thermostat (7170HM) and the fan air valve (9HA2) AMM 36-11-49-000-820 and AMM 36-11-49-400-820.
- Replace the THERMOSTAT-FAN AIR VALVE CTL [7170HM] AMM 36-11-43-000-001 and AMM 36-11-43-400-001.
* If the fault continues:
* - Replace the SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2] AMM 36-11-17-000-001 and AMM 36-11-17-400-001.
- Do a check of the wiring ASM 361102 between:
. Pin A/1 of the fan air valve (9HA2) and pin AA/12A of the BMC2 (1HA2)
. Pin A/3 of the fan air valve and the ground terminal.
- Repair the wiring.
- Replace the VALVE-FAN AIR, ENG2 [9HA2] AMM 36-11-54-000-001 and AMM 36-11-54-400-001.
B. Test
(1) Do the operational test of the bleed air system AMM 36-11-00-710-003.
(2) After the subsequent flight, make sure that the fault does not continue.
(1) Do the operational test of the bleed air system AMM 36-11-00-710-003.
(2) After the subsequent flight, make sure that the fault does not continue.