Loss of the Coupling between the HP Bleed Valve of the Engine 2 and the Related Closure Control Solenoid
TASK 36-11-00-810-842-A
Loss of the Coupling between the HP Bleed Valve of the Engine 2 and the Related Closure Control Solenoid
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-172-B ** ON A/C NOT FOR ALL
Subtask 36-11-00-810-112-C ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:44 UTC
Loss of the Coupling between the HP Bleed Valve of the Engine 2 and the Related Closure Control Solenoid
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-51-000-040 | Removal of the High Pressure Bleed Valve |
| AMM 36-11-51-400-040 | Installation of the High Pressure Bleed Valve |
| AMM 36-11-58-000-001 | Removal of the HP Bleed Override Solenoid |
| AMM 36-11-58-400-001 | Installation of the HP Bleed Override Solenoid |
Subtask 36-11-00-710-172-B ** ON A/C NOT FOR ALL
A. Not applicable.
4. Fault IsolationSubtask 36-11-00-810-112-C ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message:
HP BLEED-V 4000HA2 OR SOLENOID 11HA2
Subtask 36-11-00-710-173-B ** ON A/C NOT FOR ALL HP BLEED-V 4000HA2 OR SOLENOID 11HA2
- do a check and clean the sense line between the HP bleed valve (4000HA), the Solenoïd HP Bleed Override (11HA2) and the bleed pressure-regulator valve (4001HA).
- repair them and refer to Para. B
- replace the VALVE-HP BLEED [4000HA] AMM 36-11-51-000-040 and AMM 36-11-51-400-040.
- replace the SOL-HP BLEED OVERRIDE, ENG2 [11HA2] AMM 36-11-58-000-001 and AMM 36-11-58-400-001.
B. After the subsequent flight, make sure that the fault does not continue.