HP Bleed Valve Locked in the Not Fully Open Position on the Engine 2


TASK 36-11-00-810-840-A
HP Bleed Valve Locked in the Not Fully Open Position on the Engine 2


WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK ON THE PNEUMATIC SYSTEM.
WARNING: MAKE SURE THAT PERSONS DO NOT START THE ENGINES DURING THIS PROCEDURE; IT IS DANGEROUS TO WORK ON OR GO NEAR AN ENGINE WHEN IT OPERATES.
1. Possible Causes
  • XDCR-BLEED TRANSFER PRESS, ENG 2 [7HA2]
  • VALVE-HP BLEED [4000HA]
  • sense line between the HP bleed valve (4000HA), the bleed-pressure regulator valve (4001HA) and the solenoid (11HA2)
  • sense line between the HP bleed valve (4000HA), the bleed pressure regulator valve (4001HA) and the solenoid (11HA2)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CAP - BLANKING
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-15-000-001
Removal of the Bleed Transferred Pressure-Transducer
AMM 36-11-15-400-001
Installation of the Bleed Transferred Pressure-Transducer
AMM 36-11-15-720-001
Functional Test of the Bleed Transferred Pressure-Transducer with the Bleed Test Set P/N 98D36003000000
AMM 36-11-49-000-029
Removal of the Pneumatic Sense Lines in the Pylon
AMM 36-11-49-400-029
Installation of the Pneumatic Sense Lines in the Pylon
AMM 36-11-51-000-040
Removal of the High Pressure Bleed Valve
AMM 36-11-51-400-040
Installation of the High Pressure Bleed Valve
AMM 36-11-51-720-001
Functional Test of the HP Bleed Valve with the Bleed Test Set P/N 98D36003000000
3. Fault Confirmation
Subtask 36-11-00-710-128-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 36-11-00-810-090-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message:
361151
HP BLEED-V
4000HA2
OR SENSE LINE
   (1) If the test is not OK:
   (2) If the test is OK:
  • disconnect the sense line from the HP bleed valve of the engine 2
  • put a CAP - BLANKING on the pressure port of the sense line of the HP bleed valve
  • do a functional test of the opening of the engine 2 HP bleed valve AMM 36-11-51-720-001.
     (a) If the test is not OK:
     (b) If the test is OK:
  • replace the sense line between the HP bleed valve (4000HA), the bleed-pressure regulator valve (4001HA) and the solenoid (11HA2) of the engine 2 AMM 36-11-49-000-029 and AMM 36-11-49-400-029.
  • refer to Para. 4.B.
Subtask 36-11-00-810-090-B ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message:
361151
HP BLEED-V
4000HA2
OR SENSE LINE
   (1) If the test is not OK:
   (2) If the test is OK:
  • disconnect the sense line from the HP bleed valve of the engine 2
  • put a CAP - BLANKING on the pressure port of the sense line of the HP bleed valve
  • do a functional test of the opening of the engine 2 HP bleed valve AMM 36-11-51-720-001.
     (a) If the test is not OK:
     (b) If the test is OK:
  • replace the sense line between the HP bleed valve (4000HA), the bleed pressure regulator valve (4001HA) and the solenoid (11HA2) of the engine 2 AMM 36-11-49-000-029 and AMM 36-11-49-400-029.
  • refer to Para. 4.B.
Subtask 36-11-00-710-129-A ** ON A/C NOT FOR ALL
B. After the subsequent flight, make sure that the fault does not continue.