Loss of the Coupling between the HP Bleed Valve and the Bleed Pressure-Regulator Valve of the Engine 1


TASK 36-11-00-810-833-A
Loss of the Coupling between the HP Bleed Valve and the Bleed Pressure-Regulator Valve of the Engine 1


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 361101
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
AMM 36-11-51-000-040
Removal of the High Pressure Bleed Valve
AMM 36-11-51-000-042
Removal of the High Pressure Bleed Valve
AMM 36-11-51-400-040
Installation of the High Pressure Bleed Valve
AMM 36-11-51-400-042
Installation of the High Pressure Bleed Valve
AMM 36-11-52-000-040
Removal of the Bleed Pressure-Regulator Valve
AMM 36-11-52-000-042
Removal of the Bleed Pressure Regulator Valve
AMM 36-11-52-400-040
Installation of the Bleed Pressure-Regulator Valve
AMM 36-11-52-400-042
Installation of the Bleed Pressure Regulator Valve
AMM 36-11-52-720-001
Functional Test of the Opening of the Bleed-Pressure Regulator Valve (PRV) with the Bleed Test Set P/N 98D36003000000
3. Fault Confirmation
Subtask 36-11-00-710-114-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do the test of the bleed pressure-regulator valve AMM 36-11-52-720-001.
4. Fault Isolation
Subtask 36-11-00-810-083-C ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message:
PRESS REG-V 4001HA1 OR HP BLEED-V 4000HA1 OR SENSE LINE
and if the HP bleed valve is blocked in the open position:
  • make sure that the indication of the position of the HP bleed valve on the lower ECAM display unit is correct when you manually operate the valve shaft.
   (1) If the indication does not agree with the position of the valve butterfly:
  • do a check and repair the wiring from the HP bleed valve to the BMC1 , pin A/1 to pin AA/14A ASM 361101.
     (a) If the fault continues:
     (b) If the fault continues:
     (c) If the fault continues:
  • do a check and clean the sense line between the bleed pressure-regulator valve (4001HA), the HP bleed valve (4000HA) and the associated solenoid (11HA1).
     (d) If the fault continues:
Subtask 36-11-00-810-083-D ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message:
PRESS REG-V 4001HA1 OR HP BLEED-V 4000HA1 OR SENSE LINE
and if the HP bleed valve is blocked in the open position:
  • Make sure that the indication of the HP bleed-valveposition on the lower ECAM display unit is correct when you manually operate the valve shaft.
   (1) If the indication does not agree with the position of the valve butterfly:
  • Do a check and repair the wiring from the HP bleed valve to the BMC1 , pin A/1 to pin AA/14A ASM 361101.
     (a) If the fault continues:
     (b) If the fault continues:
     (c) If the fault continues:
  • Do a check and clean the sense line between the bleed pressure-regulator valve (4001HA) and the HP bleed valve (4000HA).
     (d) If the fault continues:
Subtask 36-11-00-710-115-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.