Loss of the Manual Electrical Closure of the Bleed Pressure-Regulator Valve of the Engine 2
TASK 36-11-00-810-832-A
Loss of the Manual Electrical Closure of the Bleed Pressure-Regulator Valve of the Engine 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-112-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-865-056-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:43 UTC
Loss of the Manual Electrical Closure of the Bleed Pressure-Regulator Valve of the Engine 2
1. Possible Causes
- VALVE-BLEED PRESS REG [4001HA]
- wiring
- BMC-2 [1HA2]
- SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2]
- P/BSW-ENG 2 BLEED [4HA2]
- wiring from the connector of the bleed pressure-regulator valve control-solenoid to the ENG 2 BLEED pushbutton switch
wiring from the ENG 2 BLEED pushbutton switch to the circuit breaker (3HA2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 36-11-00-810-830-A | Loss of the Non-Return Function and Temperature Limitation Function of the Bleed Pressure-Regulator Valve of the Engine 2 |
| ASM 361102 | |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| AMM 36-11-52-000-040 | Removal of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-000-042 | Removal of the Bleed Pressure Regulator Valve |
| AMM 36-11-52-400-040 | Installation of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-400-042 | Installation of the Bleed Pressure Regulator Valve |
| AMM 36-11-52-720-001 | Functional Test of the Opening of the Bleed-Pressure Regulator Valve (PRV) with the Bleed Test Set P/N 98D36003000000 |
| AMM 36-11-55-000-001 | Removal of the Bleed-Pressure-Regulator Valve Control-Solenoid |
| AMM 36-11-55-400-001 | Installation of the Bleed-Pressure-Regulator Valve Control-Solenoid |
Subtask 36-11-00-710-112-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-865-056-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 36-11-00-810-082-C ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
B. If the fault symptom is identified by the maintenance message:
PRESS REG-V 4001HA2 OR SOL 10HA2
Subtask 36-11-00-810-082-F ** ON A/C NOT FOR ALL PRESS REG-V 4001HA2 OR SOL 10HA2
- do a check of the visual position indicator of the bleed pressure-regulator valve.
- replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
- make sure that the indication of the valve position on the lower ECAM display unit is correct when you manually operate the valve shaft.
- Do a check and repair the wiring between the bleed pressure regulator-valve (4001HA) to the BMC2 (1HA2), pin A/5 to pin AA/2B ASM 361102.
- replace the BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- release the ENG 2 BLEED pushbutton switch
- make sure that the bleed pressure-regulator valve control-solenoid (10HA2) makes clicks.
- do a check and clean the sense line between the bleed pressure-regulator valve control-solenoid (10HA2) and the bleed pressure-regulator valve (4001HA).
- replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
- replace the SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- do a check for 28VDC at pin A/1 of the connector of the bleed pressure-regulator valve control-solenoid (10HA2) with the ENG 2 BLEED pushbutton switch (4HA2) released (OFF legend on) and the circuit breaker (2HA2) open.
- do a check for ground at pin A/3 of the connector of the bleed pressure-regulator valve control-solenoid (10HA2).
* If there is no ground signal:
* - replace the SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- do a check for 28VDC at pin A/D2 of the ENG 2 BLEED pushbutton switch (4HA2).
* If there is 28VDC:
* - do a check and repair the wiring from the connector of the bleed pressure-regulator valve control-solenoid to the control-solenoid to the ENG 2 BLEED pushbutton switch, pin A/1 to pin A/D3.
** If the fault continues:
** - replace the P/BSW-ENG 2 BLEED [4HA2] .
* If there is no 28VDC:
* - replace the circuit breaker (3HA2).
** If the fault continues:
** - do a check and repair the wiring between the ENG 2 BLEED pushbutton switch to the circuit breaker (3HA2), pin A/D2 to pin 2.
B. If the fault symptom is identified by the maintenance message:
PRESS REG-V 4001HA2 OR SOL 10HA2
Subtask 36-11-00-810-167-B ** ON A/C NOT FOR ALL PRESS REG-V 4001HA2 OR SOL 10HA2
- Do a check of the visual position indicator of the bleed pressure-regulator valve.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
- Make sure that the valve position indication on the lower ECAM display unit is correct when you manually operate the valve shaft.
- Do a check and repair the wiring between the bleed pressure-regulator valve and the BMC2, pin A/5 to pin AA/2B ASM 361102.
- Replace the BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- Release the ENG 2 BLEED pushbutton switch.
- Make sure that the bleed pressure-regulator valve control-solenoid (10HA2) makes clicks.
- Do a check and clean the sense line between the bleed pressure-regulator valve control-solenoid (10HA2) and the bleed pressure-regulator valve (4001HA).
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
- Replace the SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- Do a check for 28 VDC at pin A/1 of the connector of the bleed pressure-regulator valve control-solenoid (10HA2) with the ENG 2 BLEED pushbutton switch (4HA2) released (OFF legend on) and the circuit breaker (2HA2) open.
- Do a check for ground at pin A/3 of the connector of the bleed pressure-regulator valve control-solenoid (10HA2).
* If there is no ground signal:
* - Replace the SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- Do a check for 28 VDC at pin A/D2 of the ENG 2 BLEED pushbutton switch (4HA2) ASM 361102.
* If there is 28 VDC:
* - Do a check and repair the wiring from the connector of the bleed pressure-regulator valve control-solenoid to the ENG 2 BLEED pushbutton switch , pin A/1 to pin A/D3 ASM 361102.
** If the fault continues:
** - Replace the P/BSW-ENG 2 BLEED [4HA2] .
* If there is no 28 VDC:
* - Replace the circuit breaker (3HA2).
** If the fault continues:
** - Do a check and repair thewiring from the ENG 2 BLEED pushbutton switch to the circuit breaker (3HA2) , pin A/D2 to pin 2 ASM 361102.
C. If the test gives the maintenance message PRESS REG-V 4001HA OR SOL 10HA2 OR SENSE LINE:
Subtask 36-11-00-710-113-A ** ON A/C NOT FOR ALL - do the trouble shooting procedure for the Bleed Pressure Regulator Valve (4001HA) and the Bleed Pressure Regulator Solenoid (10HA2) (Ref. TSM TASK 36-11-00-810-830)
D. Do the test given in Para. 3.