Loss of the Manual Electrical Closure of the Bleed Pressure-Regulator Valve of the Engine 1
TASK 36-11-00-810-831-A
Loss of the Manual Electrical Closure of the Bleed Pressure-Regulator Valve of the Engine 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-110-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-865-055-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:43 UTC
Loss of the Manual Electrical Closure of the Bleed Pressure-Regulator Valve of the Engine 1
1. Possible Causes
- VALVE-BLEED PRESS REG [4001HA]
- wiring
- BMC-1 [1HA1]
- SOLENOID-BLEED PRESS REG V CTL, ENG 1 [10HA1]
- P/BSW-ENG 1 BLEED [4HA1]
- wiring from the connector of the bleed pressure-regulator valve control-solenoid to the ENG 1 BLEED pushbutton switch
wiring from the ENG 1 BLEED pushbutton switch to the circuit breaker (3HA1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 36-11-00-810-829-A | Loss of the Non-Return Function and Temperature Limitation Function of the Bleed Pressure-Regulator Valve of the Engine 1 |
| ASM 361101 | |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| AMM 36-11-52-000-040 | Removal of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-000-042 | Removal of the Bleed Pressure Regulator Valve |
| AMM 36-11-52-400-040 | Installation of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-400-042 | Installation of the Bleed Pressure Regulator Valve |
| AMM 36-11-52-720-001 | Functional Test of the Opening of the Bleed-Pressure Regulator Valve (PRV) with the Bleed Test Set P/N 98D36003000000 |
| AMM 36-11-55-000-001 | Removal of the Bleed-Pressure-Regulator Valve Control-Solenoid |
| AMM 36-11-55-400-001 | Installation of the Bleed-Pressure-Regulator Valve Control-Solenoid |
Subtask 36-11-00-710-110-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-865-055-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 36-11-00-810-081-C ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
B. If the fault symptom is identified by the maintenance message:
PRESS REG-V 4001HA1 OR SOL 10HA1
Subtask 36-11-00-810-081-F ** ON A/C NOT FOR ALL PRESS REG-V 4001HA1 OR SOL 10HA1
- do a check of the visual position indicator of the bleed pressure-regulator valve.
- replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
- make sure that the indication of the valve position on the lower ECAM display unit is correct when you manually operate the valve shaft.
- do a check and repair the wiring between the bleed pressure regulator-valve (4001HA) to the BMC1 (1HA1), pin A/5 to pin AA/2B ASM 361101.
- replace the BMC-1 [1HA1] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- release the ENG 1 BLEED pushbutton switch
- make sure that the bleed pressure-regulator valve control-solenoid (10HA1) makes clicks.
- do a check and clean the sense line between the bleed pressure-regulator valve control-solenoid (10HA1) and the bleed pressure-regulator valve (4001HA).
- replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
- replace the SOLENOID-BLEED PRESS REG V CTL, ENG 1 [10HA1] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- do a check for 28VDC at pin A/1 of the connector of the bleed pressure-regulator valve control-solenoid (10HA1) with the ENG 1 BLEED pushbutton switch (4HA1) released (OFF legend on) and the circuit breaker (2HA1) open.
- do a check for ground at pin A/3 of the connector of the bleed pressure-regulator valve control-solenoid (10HA1).
* If there is no ground signal:
* - replace the SOLENOID-BLEED PRESS REG V CTL, ENG 1 [10HA1] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- do a check for 28VDC at pin A/D2 of the ENG 1 BLEED pushbutton switch (4HA1).
* If there is 28VDC:
* - do a check and repair the wiring from the connector of the bleed pressure-regulator valve control-solenoid to the control-solenoid to the ENG 1 BLEED pushbutton switch, pin A/1 to pin A/D3.
* If the fault continues:
* - replace the P/BSW-ENG 1 BLEED [4HA1] .
* If there is no 28VDC:
* - replace the circuit breaker (3HA1).
** If the fault continues:
** - do a check and repair the wiring between the ENG 1 BLEED pushbutton switch to the circuit breaker (3HA1), pin A/D2 to pin 2.
B. If the fault symptom is identified by the maintenance message:
PRESS REG-V 4001HA1 OR SOL 10HA1
Subtask 36-11-00-810-166-B ** ON A/C NOT FOR ALL PRESS REG-V 4001HA1 OR SOL 10HA1
- Do a check of the visual position indicator of the bleed pressure-regulator valve.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
- Make sure that the valve position indication on the lower ECAM display unit is correct when you manually operate the valve shaft.
- Do a check and repair the wiring between the bleed pressure-regulator valve and the BMC1, pin A/5 to pin AA/2B ASM 361101.
- Replace the BMC-1 [1HA1] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- Release the ENG 1 BLEED pushbutton switch.
- Make sure that the bleed pressure-regulator valve control-solenoid (10HA1) makes clicks.
- Do a check and clean the sense line between the bleed pressure-regulator valve control-solenoid (10HA1) and the bleed pressure-regulator valve (4001HA).
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
- Replace the SOLENOID-BLEED PRESS REG V CTL, ENG 1 [10HA1] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- Do a check for 28 VDC at pin A/1 of the connector of the bleed pressure-regulator valve control-solenoid (10HA1) with the ENG 1 BLEED pushbutton switch (4HA1) released (OFF legend on) and the circuit breaker (2HA1) open.
- Do a check for ground at pin A/3 of the connector of the bleed pressure-regulator valve control-solenoid (10HA1).
* If there is no ground signal:
* - Replace the SOLENOID-BLEED PRESS REG V CTL, ENG 1 [10HA1] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- Do a check for 28 VDC at pin A/D2 of the ENG 1 BLEED pushbutton switch (4HA1) ASM 361101.
* If there is 28 VDC:
* - Do a check and repair the wiring from the connector of the bleed pressure-regulator valve control-solenoid to the ENG 1 BLEED pushbutton switch , pin A/1 to pin A/D3.
** If the fault continues:
** - Replace the P/BSW-ENG 1 BLEED [4HA1] .
* If there is no 28 VDC:
* - Replace the circuit breaker (3HA1).
** If the fault continues:
** - Do a check and repair thewiring from the ENG 1 BLEED pushbutton switch to the circuit breaker (3HA1) , pin A/D2 to pin 2 ASM 361101.
C. If the test gives the maintenance message:
PRESS REG-V 4001HA1 OR SOL 10HA1 OR SENSE LINE
Subtask 36-11-00-710-111-A ** ON A/C NOT FOR ALL PRESS REG-V 4001HA1 OR SOL 10HA1 OR SENSE LINE
- do the trouble shooting procedure for the Bleed Pressure Regulator Valve (4001HA) and the Bleed Pressure Regulator Solenoid (10HA1) (Ref. TSM TASK 36-11-00-810-829)
D. Do the test given in Para. 3.