Loss of One Sensing Element of the Exchanger Outlet Temperature-Sensor of the Engine 2
TASK 36-11-00-810-826-A
Loss of One Sensing Element of the Exchanger Outlet Temperature-Sensor of the Engine 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-104-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-810-078-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:42 UTC
Loss of One Sensing Element of the Exchanger Outlet Temperature-Sensor of the Engine 2
1. Possible Causes
- SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2]
wiring between pin A/1 of the exchanger outlet temperature-sensor (6HA2) and the ground terminal wiring from the exchanger outlet temperature-sensor (6HA2) to the BMC2 (1HA2) - BMC-2 [1HA2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 361102 | |
| AMM 36-11-17-000-001 | Removal of the Heat-Exchanger Outlet-Temperature Sensor |
| AMM 36-11-17-400-001 | Installation of the Heat-Exchanger Outlet-Temperature Sensor |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
Subtask 36-11-00-710-104-A ** ON A/C NOT FOR ALL
A. Test.
(1) Not applicable, the fault is evident.
4. Fault Isolation(1) Not applicable, the fault is evident.
Subtask 36-11-00-810-078-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message:
TEMP SENSOR 6HA2:
Subtask 36-11-00-710-105-A ** ON A/C NOT FOR ALL TEMP SENSOR 6HA2:
- replace the SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2] AMM 36-11-17-000-001 and AMM 36-11-17-400-001.
- do a check for ground at pin A/1 of the exchanger outlet temperature-sensor of the engine 2.
- do a check and repair the
wiring between pin A/1 of the exchanger outlet temperature-sensor (6HA2) and the ground terminal ASM 361102.
- do a check and repair the
wiring from the exchanger outlet temperature-sensor (6HA2) to the BMC2 (1HA2) , pins A/2 and A/4 to pins AA/9B and AA/10B.
- replace the BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
B. After the subsequent flight, make sure that the fault does not continue.