Bleed Pressure-Regulator Valve of the Engine 2 not Fully Closed
TASK 36-11-00-810-824-A
Bleed Pressure-Regulator Valve of the Engine 2 not Fully Closed
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-080-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-810-066-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:42 UTC
Bleed Pressure-Regulator Valve of the Engine 2 not Fully Closed
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-16-000-001 | Removal of the Bleed Regulated Pressure-Transducer |
| AMM 36-11-16-400-001 | Installation of the Bleed Regulated Pressure-Transducer |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| AMM 36-11-52-000-040 | Removal of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-400-040 | Installation of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-720-001 | Functional Test of the Opening of the Bleed-Pressure Regulator Valve (PRV) with the Bleed Test Set P/N 98D36003000000 |
Subtask 36-11-00-710-080-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-810-066-B ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message:
PRESS REG-V 4001HA2
and if the bleed pressure-regulator valve is not fully closed:
Subtask 36-11-00-710-081-A ** ON A/C NOT FOR ALL PRESS REG-V 4001HA2
and if the bleed pressure-regulator valve is not fully closed:
- do a check of the bleed pressure indication on the lower ECAM display unit.
- do a check for ground at pin A/5 of the bleed pressure-regulator valve (4001HA).
- repair the wiring between pin A/5 of the bleed pressure-regulator valve (4001HA) and the ground terminal.
- replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
- do a check for ground at pin AA/2B of the BMC2 (1HA2).
- do a check and repair the wiring between the BMC2 (1HA2) to the bleed pressure-regulator valve (4001HA) pin AA/2B to pin A/5.
- replace the BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- replace the XDCR-BLEED REGULATED PRESS, ENG 2 [8HA2] AMM 36-11-16-000-001 and AMM 36-11-16-400-001.
B. Do the test given in Para. 3.