W DOC AIRBUS | TSM A320F

Bleed Pressure-Regulator Valve of the Engine 1 not Fully Closed


TASK 36-11-00-810-823-A
Bleed Pressure-Regulator Valve of the Engine 1 not Fully Closed


1. Possible Causes
  • wiring
  • VALVE-BLEED PRESS REG [4001HA]
  • BMC-1 [1HA1]
  • XDCR-BLEED REGULATED PRESS, ENG 1 [8HA1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-16-000-001
Removal of the Bleed Regulated Pressure-Transducer
AMM 36-11-16-400-001
Installation of the Bleed Regulated Pressure-Transducer
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
AMM 36-11-52-000-040
Removal of the Bleed Pressure-Regulator Valve
AMM 36-11-52-400-040
Installation of the Bleed Pressure-Regulator Valve
AMM 36-11-52-720-001
Functional Test of the Opening of the Bleed-Pressure Regulator Valve (PRV) with the Bleed Test Set P/N 98D36003000000
3. Fault Confirmation
Subtask 36-11-00-710-426-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do the test of the bleed pressure-regulator valve AMM 36-11-52-720-001.
4. Fault Isolation
Subtask 36-11-00-810-065-B ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message:
PRESS REG-V 4001HA1
and if the bleed pressure-regulator valve is not fully closed:
  • do a check of the bleed pressure indication on the lower ECAM display unit.
   (1) If the indication is correct (0 psig) with no air supply:
  • do a check for ground at pin A/5 of the bleed pressure-regulator valve (4001HA).
     (a) If there is no ground signal:
  • repair the wiring between pin A/5 of the bleed pressure-regulator valve (4001HA) and the ground terminal.
       1 If the fault continues:
     (b) If there is a ground signal:
  • do a check for ground at pin AA/2B of the BMC1 (1HA1).
       1 If there is no ground signal:
  • do a check and repair the wiring between the BMC1 (1HA1) to the bleed pressure-regulator valve (4001HA) pin AA/2B to pin A/5.
       2 If there is a ground signal:
   (2) If the indication is not correct with no air supply:
Subtask 36-11-00-710-079-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:42 UTC