Bleed Pressure-Regulator Valve of the Engine 2 Blocked in the Closed Position or Regulation Too Low
TASK 36-11-00-810-810-A
Bleed Pressure-Regulator Valve of the Engine 2 Blocked in the Closed Position or Regulation Too Low
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-052-A ** ON A/C NOT FOR ALL 4. Fault Isolation
[Rev.8 from Aug 2018]
2026.04.04 04:33:41 UTC
Bleed Pressure-Regulator Valve of the Engine 2 Blocked in the Closed Position or Regulation Too Low
1. Possible Causes
- BMC-2 [1HA2]
- VALVE-BLEED PRESS REG [4001HA]
sense line between the bleed-pressure regulator valve (4001HA) and the solenoid (10HA2) - O-RING
- SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2]
- XDCR-BLEED REGULATED PRESS, ENG 2 [8HA2]
- XDCR-BLEED TRANSFER PRESS, ENG 2 [7HA2]
- VALVE-HP BLEED [4000HA]
- P/BSW-ENG 2 BLEED [4HA2]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CAP - BLANKING |
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 204511 | |
| AMM 36-11-00-720-007 | Functional Test of the Sense Lines Connected to the Bleed Pressure-Regulator Valve with the Bleed Test Set P/N 98D36003000000 |
| AMM 36-11-00-740-001 | BITE Test of the BMC 1(2) |
| AIPC 36110606 | |
| AMM 36-11-15-000-001 | Removal of the Bleed Transferred Pressure-Transducer |
| AMM 36-11-15-400-001 | Installation of the Bleed Transferred Pressure-Transducer |
| AMM 36-11-16-000-001 | Removal of the Bleed Regulated Pressure-Transducer |
| AMM 36-11-16-400-001 | Installation of the Bleed Regulated Pressure-Transducer |
| AMM 36-11-49-000-029 | Removal of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-49-000-820 | Removal of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-49-400-029 | Installation of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-49-400-820 | Installation of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-51-000-040 | Removal of the High Pressure Bleed Valve |
| AMM 36-11-51-000-042 | Removal of the High Pressure Bleed Valve |
| AMM 36-11-51-400-040 | Installation of the High Pressure Bleed Valve |
| AMM 36-11-51-400-042 | Installation of the High Pressure Bleed Valve |
| AMM 36-11-52-000-040 | Removal of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-000-042 | Removal of the Bleed Pressure Regulator Valve |
| AMM 36-11-52-400-040 | Installation of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-400-042 | Installation of the Bleed Pressure Regulator Valve |
| AMM 36-11-52-720-001 | Functional Test of the Opening of the Bleed-Pressure Regulator Valve (PRV) with the Bleed Test Set P/N 98D36003000000 |
| AMM 36-11-55-000-001 | Removal of the Bleed-Pressure-Regulator Valve Control-Solenoid |
| AMM 36-11-55-400-001 | Installation of the Bleed-Pressure-Regulator Valve Control-Solenoid |
| AMM 36-11-58-100-803 | Cleaning of the Sense Line between the HP Bleed-Override Solenoid and the Pressure Regulating Valve (PRV) |
Subtask 36-11-00-710-052-A ** ON A/C NOT FOR ALL 4. Fault Isolation
CAUTION:
BE CAREFUL WITH THE SEMI-FLEXIBLE SENSE LINE. DEFORMATION OF THE RIGID PART OR LARGE DEFORMATION OF THE FLEXIBLE PART CAN QUICKLY CAUSE LEAKAGE.
CAUTION:
USE TWO WRENCHES DURING DISCONNECTION OF THE SENSE LINE, ONE TO MAINTAIN THE FIXED NUT AND THE SECOND ONE TO LOOSEN/TIGHTEN THE SENSE LINE COUPLING.
Subtask 36-11-00-810-266-A ** ON A/C NOT FOR ALL A. If the BITE test gives a fault message related to the BMC-2 [1HA2]
Subtask 36-11-00-810-051-H ** ON A/C NOT FOR ALL - Do the related trouble shooting procedure.
DELETED
Subtask 36-11-00-810-051-I ** ON A/C NOT FOR ALL B. If the test do not give a fault message related to the BMC2 and if the fault is identified by the maintenance message
PRESS REG-V 4001HA2 OR SOL 10HA2 OR SENSE LINE:
Subtask 36-11-00-810-051-L ** ON A/C NOT FOR ALL PRESS REG-V 4001HA2 OR SOL 10HA2 OR SENSE LINE:
- Do a check of the sense line unions and the clamps between the bleed- pressure regulator valve (4001HA) and the solenoid (10HA2).
- Tighten them.
- Do a check of the opening of the bleed-pressure regulator valve AMM 36-11-52-720-001.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
- Do a leakage check of the sense line between the bleed-pressure regulator valve and the control solenoid of the bleed-pressure regulator valve AMM 36-11-00-720-007.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
- Do an internal leak check of the control solenoid bleed-pressure regulator valve.
- Disconnect the sense line at the control solenoid of the bleed-pressure regulator valve.
- Put a CAP - BLANKING on the sense line.
- Pressurize the sense line to 2.07 bar (30 psi), then close the shutoff valve of the pressure source.
- Repair or replace the
sense line between the bleed-pressure regulator valve (4001HA) and the solenoid (10HA2) AMM 36-11-49-000-820 and AMM 36-11-49-400-820.
- Remove the bleed-pressure-regulator valve control-solenoid AMM 36-11-55-000-001.
- Do a visual inspection of the O-ring at the bottom of the bleed-pressure-regulator valve control-solenoid.
* If the O-ring is damaged:
** Install a new O-RING AIPC 36110606.
** Install the bleed-pressure-regulator valve control-solenoid AMM 36-11-55-400-001.
* If the O-ring has no damage:
** Install a new O-RING AIPC 36110606.
** Replace the SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2] AMM 36-11-55-400-001.
- Do a check of the correct indication of the bleed-regulated pressure transducer (8HA2).
- On the AIR control panel 30VU, push the APU BLEED pushbutton switch and set the X-BLEED selector switch to OPEN.
- On the ECAM BLEED page, do a check of the pressure indications of the two systems.
- Replace the XDCR-BLEED REGULATED PRESS, ENG 2 [8HA2] AMM 36-11-16-000-001 and AMM 36-11-16-400-001.
- Replace the XDCR-BLEED TRANSFER PRESS, ENG 2 [7HA2] AMM 36-11-15-000-001 and AMM 36-11-15-400-001.
- Replace the VALVE-HP BLEED [4000HA] AMM 36-11-51-000-042 and AMM 36-11-51-400-042.
- Replace the P/BSW-ENG 2 BLEED [4HA2] ESPM 204511.
B. If the test do not give a fault message related to the BMC2 and if the fault is identified by the maintenance message
PRESS REG-V 4001HA2 or SOL 10HA2 or SENSE LINE:
Subtask 36-11-00-710-053-A ** ON A/C NOT FOR ALL PRESS REG-V 4001HA2 or SOL 10HA2 or SENSE LINE:
- Do a check of the sense line unions and the clamps between the bleed-pressure regulator valve (4001HA) and the solenoid (10HA2).
- Tighten them.
- Do a check of the opening of the bleed-pressure regulator valve AMM 36-11-52-720-001.
- Do the cleaning of the sense line between the HP bleed-override solenoid and the bleed-pressure regulator valve AMM 36-11-58-100-803.
- Do a check of the opening of the bleed-pressure regulator valve AMM 36-11-52-720-001.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
- Do a leak check of the sense line between the bleed-pressure regulator valve and the control solenoid of the bleed-pressure regulator valve AMM 36-11-00-720-007.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
- Do an internal leak check of the control solenoid of the bleed-pressure regulator valve.
- Disconnect the sense line at the control solenoid of the bleed-pressure regulator valve.
- Put a CAP - BLANKING on the sense line.
- Pressurize the sense line to 2.07 bar (30 psi), then close the shutoff valve of the pressure source.
- Repair or replace the
sense line between the bleed-pressure regulator valve (4001HA) and the solenoid (10HA2) AMM 36-11-49-000-029 and AMM 36-11-49-400-029.
- Remove the bleed-pressure-regulator valve control-solenoid AMM 36-11-55-000-001.
- Do a visual inspection of the O-ring at the bottom of the bleed-pressure-regulator valve control-solenoid.
* If the O-ring is damaged:
** Install a new O-RING AIPC 36110606.
** Install the bleed-pressure-regulator valve control-solenoid AMM 36-11-55-400-001.
* If the O-ring has no damage:
** Install a new O-RING AIPC 36110606.
** Replace the SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2] AMM 36-11-55-400-001.
- Do a check of the correct indication of the bleed-regulated pressure transducer (8HA2).
- On the AIR control panel 30VU, push the APU BLEED pusbhutton switch and set the X-BLEED selector switch to OPEN.
- On the ECAM BLEED page, do a check of the pressure indications of the two systems.
- Replace the XDCR-BLEED REGULATED PRESS, ENG 2 [8HA2] AMM 36-11-16-000-001 and AMM 36-11-16-400-001.
- Replace the XDCR-BLEED TRANSFER PRESS, ENG 2 [7HA2] AMM 36-11-15-000-001 and AMM 36-11-15-400-001.
- Replace the VALVE-HP BLEED [4000HA] AMM 36-11-51-000-040 and AMM 36-11-51-400-040.
- Replace the P/BSW-ENG 2 BLEED [4HA2] ESPM 204511.
C. After the subsequent flight, make sure that the fault does not continue.