W DOC AIRBUS | TSM A320F

Loss of the BMC2


TASK 36-11-00-810-804-A
Loss of the BMC2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
3. Fault Confirmation
Subtask 36-11-00-710-088-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the BMC2 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-11-00-810-070-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
BMC2
Subtask 36-11-00-710-089-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.