W DOC AIRBUS | TSM A320F

Incorrect AIR BLEED generation


TASK 36-00-00-810-802-A
Incorrect AIR BLEED generation


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-860-011
Procedure to Get Access to the SYSTEM REPORT/TEST/PNEU Page
ASM 315403
ASM 361103
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
3. Fault Confirmation
Subtask 36-00-00-865-050-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
49VUFWS/FWC1/SPLY3WWF01
121VUEIS/FWC2/SPLY2WWQ07
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
Subtask 36-00-00-710-051-A ** ON A/C NOT FOR ALL
B. Test
   (1) Not Applicable
4. Fault Isolation
Subtask 36-00-00-810-051-A ** ON A/C NOT FOR ALL
A. If the AIR BLEED status maintenance comes into view on the ECAM STATUS page without a CFDS fault message:
  • Open the circuit breakers 2WW and 3WW for 5 to 10 seconds to cancel the AIR BLEED status maintenance, then close them.
NOTE: 1: Approximately 2 minutes are necessary for the full initialization of the FWCs.
NOTE: 2: The reset of the BMCs (Bleed Monitoring Computers) will not cancel the AIR BLEED status maintenance on the ECAM STATUS page. If this status maintenance came into view after a power transfer, it can go out of view after the first subsequent engine start and will not come into view again after engine shutdown.
NOTE: 3: The AIR BLEED status maintenance is applicable when it is shown, after engine shutdown, in the POST FLIGHT Report as an ECAM warning with the related CFDS fault message.
NOTE: 4: To erase the AIR BLEED, the only condition is to start the FWC Flight phase 1. After the engine shutdown, the A/C will be in Flight phase 10. Three hundred seconds later, the start of the Flight phase 1 should reset the AIR BLEED.
   (1) If the fault continues:
  • On one MCDU, get the SYSTEM REPORT/TEST PNEU menu page AMM 31-32-00-860-011.
  • On one MCDU, push the line key adjacent to the BMC1(2) indication.
     (a) If the BMC1(2) page does not come into view:
  • Do a check of the wiring ASM 361103 and ASM 315403 between:
    . Pin AA/10C of the BMC1 (1HA1) and pin AB/12G of the SDAC1(2) (1WV1(2))
    . Pin AA/11C of the BMC1 (1HA1) and pin AB/12H of the SDAC1(2) (1WV1(2))
    . Pin AA/10C of the BMC2 (1HA2) and pin AE/12C of the SDAC1(2) (1WV1(2))
    . Pin AA/11C of the BMC2 (1HA2) and pin AE/12D of the SDAC1(2) (1WV1(2)).
       1 If the wiring is not correct:
  • Repair the wiring .
       2 If the wiring is correct:
     (b) If the BMC1(2) page comes into view:
NOTE: The AIR BLEED status maintenance on the ECAM STATUS page is an unwanted message. You can ignore it.
  • Open the AIR BLEED/ENG 1/MONG (2HA1) and AIR BLEED/ENG 1/CTL (3HA1) circuit breakers and the AIR BLEED/ENG 2/MONG (2HA2) and AIR BLEED/ENG 2/CTL (3HA2) circuit breakers during 5 to 10 seconds, then close them.
[Rev.8 from Aug 2018] 2026.04.04 04:33:39 UTC