Emergency Oxygen Container Fault
TASK 35-23-00-810-807-A
Emergency Oxygen Container Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 35-23-00-710-062-A 4. Fault Isolation
Subtask 35-23-00-810-059-A
Subtask 35-23-00-860-056-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:39 UTC
Emergency Oxygen Container Fault
1. Possible Causes
- OXYGEN BOX
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 35-21-41-000-001 | Removal of the Emergency Oxygen Containers |
| AMM 35-21-41-400-001 | Installation of the Emergency Oxygen Containers |
| AMM 35-23-00-710-001 | Operational Check of Manual Mask Release |
| ASM 352301 | |
| ASM 352302 |
Subtask 35-23-00-710-062-A 4. Fault Isolation
Subtask 35-23-00-810-059-A
A. If the test confirms the fault:
(a) Do a check and repair the wiring if necessary between:
Subtask 35-23-00-710-063-A - Replace the related OXYGEN BOX AMM 35-21-41-000-001 and AMM 35-21-41-400-001.
(a) Do a check and repair the wiring if necessary between:
- The related OXYGEN BOX and the related CB
- The related OXYGEN BOX and GND,
ASM 352301, ASM 352302 and ASM 352302.
B. Do the test as given in the Para. 3.A.
5. Close-upSubtask 35-23-00-860-056-A
A. Put the aircraft back to its initial configuration.