W DOC AIRBUS | TSM A320F

Power Supply Line Fault


TASK 35-23-00-810-804-A
Power Supply Line Fault


1. Possible Causes
  • RELAY-PWR SPLY (10WR)
  • wiring
  • RELAY-TIME DELAY (25WR)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 35-23-00-710-001
Operational Check of Manual Mask Release
ASM 352301
3. Fault Confirmation
Subtask 35-23-00-710-056-A
A. Do the operational test of the manual mask release AMM 35-23-00-710-001.
4. Fault Isolation
Subtask 35-23-00-810-054-A
A. If one set of masks (approx. half of the installed masks) drops after approx. 6 seconds:
  • Do a check of the RELAY-PWR SPLY (10WR) and replace it if necessary ASM 352301.
   (1) If the fault continues:
     (a) Do a check and repair the wiring if necessary between:
  • RELAY (10WR) connector A/D1 and CB (4WR)
  • RELAY (10WR) connector A/D2 RELAY (25WR) connector A/A2
  • RELAY (10WR) connector A/C1 and CB (5WR)
  • RELAY (10WR) connector A/C2 RELAY (25WR) connector A/A1
  • RELAY (10WR) connector A/B1 and CB (6WR)
  • RELAY (10WR) connector A/B2 RELAY (25WR) connector A/B1
  • RELAY (10WR) connector A/A1 and CB (7WR)
  • RELAY (10WR) connector A/A2 RELAY (25WR) connector A/B2,
    ASM 352301.
Subtask 35-23-00-810-060-A
B. If one set of masks (approx. half of the installed masks) does not fall during the test:
  • Do a check of the RELAY-PWR SPLY (10WR) and replace it if necessary ASM 352301.
   (1) If the fault continues:
  • Do a check of the RELAY-TIME DELAY (25WR) and replace it if necessary ASM 352301.
   (2) If the fault continues:
     (a) Do a check and repair the wiring if necessary between:
  • RELAY (10WR) connector A/D1 and CB (4WR)
  • RELAY (10WR) connector A/D2 and RELAY (25WR) connector A/A2
  • RELAY (10WR) connector A/C1 and CB (5WR)
  • RELAY (10WR) connector A/C2 and RELAY (25WR) connector A/A1
  • RELAY (10WR) connector A/B1 and CB (6WR)
  • RELAY (10WR) connector A/B2 and RELAY (25WR) connector A/B1
  • RELAY (10WR) connector A/A1 and CB (7WR)
  • RELAY (10WR) connector A/A2 and RELAY (25WR) connector A/B2
  • RELAY (25WR) connector A/X1 and CB (3WR)
  • RELAY (25WR) connector A/X1 and CB (2WR)
  • RELAY (25WR) connector A/X2 and GND,
    ASM 352301.
Subtask 35-23-00-710-057-A
C. Do the test as given in the Para. 3.A.
5. Close-up
Subtask 35-23-00-860-053-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:33:39 UTC