Left Flap Door of the Oxygen-Mask Stowage-Box Inoperative
TASK 35-10-00-810-829-A
Left Flap Door of the Oxygen-Mask Stowage-Box Inoperative
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 35-10-00-700-067-A
Subtask 35-10-00-810-085-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:38 UTC
Left Flap Door of the Oxygen-Mask Stowage-Box Inoperative
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 35-12-41-200-001 | Detailed Inspection of Oxygen Masks (out of box) with Harness Inflated |
| AMM 35-12-41-600-801 | Lubrication of the Left Flap Door of the Oxygen-Mask Stowage Box |
Subtask 35-10-00-700-067-A
A. Test
(1) Do the detailed inspection of the oxygen mask (out of box) with harness inflated AMM 35-12-41-200-001.
4. Fault Isolation(1) Do the detailed inspection of the oxygen mask (out of box) with harness inflated AMM 35-12-41-200-001.
Subtask 35-10-00-810-085-A
A. If during the inspection:
(1) The left flap door of the applicable oxygen-mask stowage-box is inoperative, lubricate the left flap door AMM 35-12-41-600-801.
Subtask 35-10-00-700-068-A (1) The left flap door of the applicable oxygen-mask stowage-box is inoperative, lubricate the left flap door AMM 35-12-41-600-801.
B. Do the test given in Para. 3.