Disagree between the OXY Indication on the SD page and the OFF legend on the Pushbutton Switch
TASK 35-10-00-810-816-A
Disagree between the OXY Indication on the SD page and the OFF legend on the Pushbutton Switch
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 35-10-00-710-064-A
Subtask 35-10-00-810-065-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:37 UTC
Disagree between the OXY Indication on the SD page and the OFF legend on the Pushbutton Switch
1. Possible Causes
P/BSW- OXYGEN/CREW SUPPLY(2HT) ground signal at pin A/A3 of the pushbutton switch (2HT) P/BSW-OXYGEN/CREW SUPPLY (2HT) wiring from the pushbutton switch (2HT) pin A/A2 to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 351301 |
Subtask 35-10-00-710-064-A
A. Test
Not applicable.
4. Fault IsolationNot applicable.
Subtask 35-10-00-810-065-A
A. If the OFF legend is on and the OXY indication is shown in white (DOOR/OXY Page)
Subtask 35-10-00-810-066-A - replace the
P/BSW- OXYGEN/CREW SUPPLY(2HT) .
- do a check of the wiring from the pushbutton switch (2HT) pin A/A2 to the first terminal block ASM 351301.
- repair the above wiring.
- do a check and repair the
ground signal at pin A/A3 of the pushbutton switch (2HT) ASM 351301.
B. If the OXY indication is shown in amber (DOOR/OXY Page) and the OFF legend is off (pushbutton switch pushed).
- replace the
P/BSW-OXYGEN/CREW SUPPLY (2HT) >
- do a check and repair the
wiring from the pushbutton switch (2HT) pin A/A2 to the first terminal block ASM 351301.