W DOC AIRBUS | TSM A320F

Flap Door of the Mask Stowage-Box Inoperative


TASK 35-10-00-810-812-A
Flap Door of the Mask Stowage-Box Inoperative


1. Possible Causes
  • STOWAGE BOX-OXY MASK, CAPT [10RN1]
  • STOWAGE BOX-OXY MASK, F/O [10RN2]
  • STOWAGE BOX-OXY MASK, 3RD OCCPNT [10RN3]
  • STOWAGE BOX-OXY MASK, 4TH OCCPNT [5774HM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 35-12-41-000-001
Removal of the Oxygen-Mask Stowage-Box
AMM 35-12-41-200-001
Detailed Inspection of Oxygen Masks (out of box) with Harness Inflated
AMM 35-12-41-400-001
Installation of the Oxygen-Mask Stowage-Box
3. Fault Confirmation
Subtask 35-10-00-700-057-A
A. Test
   (1) Do the visual inspection of the flight crew oxygen mask (out of box) AMM 35-12-41-200-001.
4. Fault Isolation
Subtask 35-10-00-810-061-B
A. If during the inspection:
   (1) The flap door of the Captain mask stowage-box is deteriorated or inoperative:
   (2) The flap door of the First Officer mask stowage-box is deteriorated or inoperative:
   (3) The flap door of the Third Occupant mask stowage-box is deteriorated or inoperative:
   (4) The flap door of the Fourth Occupant mask stowage-box is deteriorated or inoperative:
Subtask 35-10-00-700-058-A
B. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:33:35 UTC