W DOC AIRBUS | TSM A320F

Crew Oxygen Pressure Indication with Amber Pressure Value and Amber Half Box on the DOOR/OXY Page


TASK 35-10-00-810-811-A
Crew Oxygen Pressure Indication with Amber Pressure Value and Amber Half Box on the DOOR/OXY Page


1. Possible Causes
  • XMTR/PRESS REG-OXY [4HT]
  • CYLINDER-OXYGEN STORAGE [5750HM]
  • OXYGEN CYLINDER [5750HM1]
  • PRESS.TRANSM.REGULATO [4HT2]
  • OXYGEN CYLINDER [5750HM2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 12-14-35-600-001
Servicing of the Oxygen-Replenishing
AMM 12-14-35-600-002
Servicing of the Oxygen-Replenishing
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
AMM 31-60-00-860-001
EIS Start Procedure
AMM 31-60-00-860-002
EIS Stop Procedure
AMM 35-10-00-720-001
Functional Check of ECAM Oxygen-Cylinder Contents Indication Compared with Cylinder Pressure Gauge
AMM 35-11-41-000-001
Removal of the Crew Oxygen-Storage Cylinder
AMM 35-11-41-000-802
Removal of the Crew Oxygen-Storage Cylinders
AMM 35-11-41-400-001
Installation of the Crew Oxygen-Storage Cylinder
AMM 35-11-41-400-802
Installation of the Crew Oxygen-Storage Cylinders
AMM 35-13-15-000-001
Removal of the Oxygen Pressure Regulator/Transmitter
AMM 35-13-15-000-802
Removal of the Oxygen Pressure Regulator/Transmitters
AMM 35-13-15-400-001
Installation of the Oxygen Pressure Regulator/Transmitter
AMM 35-13-15-400-802
Installation of the Oxygen Pressure Regulator/Transmitters
3. Fault Confirmation
Subtask 35-10-00-860-058-A
A. Job Set Up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
     (b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 35-10-00-865-059-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUOXYGEN/CREW/OXY/SPLY1HTHA01
Subtask 35-10-00-700-055-A ** ON A/C NOT FOR ALL
C. Test
   (1) On the ECAM control panel:
  • Push the DOOR key to get the DOOR/OXY page.
   (2) Make sure that the oxygen pressure value is amber and that you can see an amber half box on it.
   (3) Compare the ECAM oxygen-cylinder pressure-indication with the oxygen-cylinder pressure-gage indication on the oxygen cylinder AMM 35-10-00-720-001.
Subtask 35-10-00-700-055-B ** ON A/C NOT FOR ALL
C. Test
   (1) On the ECAM control panel:
  • Push the DOOR key to get the DOOR/OXY page.
   (2) Make sure that there is (are) amber pressure value(s) and amber half box(es) on the DOOR/OXY page.
NOTE: The pressure indication given on the left side of the lower ECAM DU is for the Captain and the Third Occupant and comes from the oxygen cylinder 5750HM1. The pressure indication given on the right side of the lower ECAM DU is for the First Officer and the Fourth Occupant and comes from the oxygen cylinder 5750HM2.
   (3) Compare the ECAM oxygen-cylinder pressure-indications with the oxygen-cylinder pressure-gage indications on the related oxygen cylinder AMM 35-10-00-720-001.
4. Fault Isolation
Subtask 35-10-00-810-060-B ** ON A/C NOT FOR ALL
A. If, during the check of the pressure of the crew oxygen-storage cylinder (5750HM), the value on the pressure gage is:
   (1) The same as the value on the SD, on the DOOR/OXY page:
   (2) Different from the value on the SD, on the DOOR/OXY page:
     (a) If the fault continues:
Subtask 35-10-00-810-060-D ** ON A/C NOT FOR ALL
A. If, during the check of the pressure of the crew oxygen-storage cylinder (5750HM1), the value on the pressure gage is:
   (1) The same as the value on the SD, on the DOOR/OXY page:
   (2) Different from the value on the SD, on the DOOR/OXY page:
     (a) If the fault continues:
Subtask 35-10-00-810-088-B ** ON A/C NOT FOR ALL
B. If, during the check of the pressure of the crew oxygen-storage cylinder (5750HM2), the value on the pressure gage is:
   (1) The same as the value on the SD, on the DOOR/OXY page:
   (2) Different from the value on the SD, on the DOOR/OXY page:
     (a) If the fault continues:
Subtask 35-10-00-700-056-A
C. Test
   (1) Make sure that there is no amber pressure value and no amber half box on the DOOR/OXY page.
5. Close-up
Subtask 35-10-00-860-059-A
A. Put the aircraft back to its initial configuration.
   (1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
AMM 31-60-00-860-002.
   (2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
[Rev.8 from Aug 2018] 2026.04.04 04:33:35 UTC