Crew Oxygen Pressure Indication with Amber Pressure Value and Amber Half Box on the DOOR/OXY Page
TASK 35-10-00-810-811-A
Crew Oxygen Pressure Indication with Amber Pressure Value and Amber Half Box on the DOOR/OXY Page
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 35-10-00-860-058-A
Subtask 35-10-00-810-060-B ** ON A/C NOT FOR ALL
Subtask 35-10-00-860-059-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:35 UTC
Crew Oxygen Pressure Indication with Amber Pressure Value and Amber Half Box on the DOOR/OXY Page
1. Possible Causes
- XMTR/PRESS REG-OXY [4HT]
- CYLINDER-OXYGEN STORAGE [5750HM]
- OXYGEN CYLINDER [5750HM1]
- PRESS.TRANSM.REGULATO [4HT2]
- OXYGEN CYLINDER [5750HM2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 12-14-35-600-001 | Servicing of the Oxygen-Replenishing |
| AMM 12-14-35-600-002 | Servicing of the Oxygen-Replenishing |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 31-60-00-860-002 | EIS Stop Procedure |
| AMM 35-10-00-720-001 | Functional Check of ECAM Oxygen-Cylinder Contents Indication Compared with Cylinder Pressure Gauge |
| AMM 35-11-41-000-001 | Removal of the Crew Oxygen-Storage Cylinder |
| AMM 35-11-41-000-802 | Removal of the Crew Oxygen-Storage Cylinders |
| AMM 35-11-41-400-001 | Installation of the Crew Oxygen-Storage Cylinder |
| AMM 35-11-41-400-802 | Installation of the Crew Oxygen-Storage Cylinders |
| AMM 35-13-15-000-001 | Removal of the Oxygen Pressure Regulator/Transmitter |
| AMM 35-13-15-000-802 | Removal of the Oxygen Pressure Regulator/Transmitters |
| AMM 35-13-15-400-001 | Installation of the Oxygen Pressure Regulator/Transmitter |
| AMM 35-13-15-400-802 | Installation of the Oxygen Pressure Regulator/Transmitters |
Subtask 35-10-00-860-058-A
A. Job Set Up
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 35-10-00-865-059-A (1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 35-10-00-700-055-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | OXYGEN/CREW/OXY/SPLY | 1HT | HA01 |
C. Test
(1) On the ECAM control panel:
(3) Compare the ECAM oxygen-cylinder pressure-indication with the oxygen-cylinder pressure-gage indication on the oxygen cylinder AMM 35-10-00-720-001.
Subtask 35-10-00-700-055-B ** ON A/C NOT FOR ALL (1) On the ECAM control panel:
- Push the DOOR key to get the DOOR/OXY page.
(3) Compare the ECAM oxygen-cylinder pressure-indication with the oxygen-cylinder pressure-gage indication on the oxygen cylinder AMM 35-10-00-720-001.
C. Test
(1) On the ECAM control panel:
4. Fault Isolation(1) On the ECAM control panel:
- Push the DOOR key to get the DOOR/OXY page.
NOTE: The pressure indication given on the left side of the lower ECAM DU is for the Captain and the Third Occupant and comes from the oxygen cylinder 5750HM1. The pressure indication given on the right side of the lower ECAM DU is for the First Officer and the Fourth Occupant and comes from the oxygen cylinder 5750HM2.
(3) Compare the ECAM oxygen-cylinder pressure-indications with the oxygen-cylinder pressure-gage indications on the related oxygen cylinder AMM 35-10-00-720-001. Subtask 35-10-00-810-060-B ** ON A/C NOT FOR ALL
A. If, during the check of the pressure of the crew oxygen-storage cylinder (5750HM), the value on the pressure gage is:
(1) The same as the value on the SD, on the DOOR/OXY page:
Subtask 35-10-00-810-060-D ** ON A/C NOT FOR ALL (1) The same as the value on the SD, on the DOOR/OXY page:
- At the oxygen filling port (5769HM), fill the crew oxygen-storage cylinder (5750HM) AMM 12-14-35-600-001 or AMM 12-14-35-600-002.
- Replace the XMTR/PRESS REG-OXY [4HT] AMM 35-13-15-000-001 and AMM 35-13-15-400-001.
- Replace the CYLINDER-OXYGEN STORAGE [5750HM] AMM 35-11-41-000-001 and AMM 35-11-41-400-001.
A. If, during the check of the pressure of the crew oxygen-storage cylinder (5750HM1), the value on the pressure gage is:
(1) The same as the value on the SD, on the DOOR/OXY page:
Subtask 35-10-00-810-088-B ** ON A/C NOT FOR ALL (1) The same as the value on the SD, on the DOOR/OXY page:
- Fill the crew oxygen cylinder (5750HM1) AMM 12-14-35-600-001.
- Replace the XMTR/PRESS REG-OXY [4HT] AMM 35-13-15-000-802 and AMM 35-13-15-400-802.
- Replace the OXYGEN CYLINDER [5750HM1] AMM 35-11-41-000-802 and AMM 35-11-41-400-802.
B. If, during the check of the pressure of the crew oxygen-storage cylinder (5750HM2), the value on the pressure gage is:
(1) The same as the value on the SD, on the DOOR/OXY page:
Subtask 35-10-00-700-056-A (1) The same as the value on the SD, on the DOOR/OXY page:
- Fill the crew oxygen cylinder (5750HM2) AMM 12-14-35-600-001.
- Replace the PRESS.TRANSM.REGULATO [4HT2] AMM 35-13-15-000-802 and AMM 35-13-15-400-802.
- Replace the OXYGEN CYLINDER [5750HM2] AMM 35-11-41-000-802 and AMM 35-11-41-400-802.
C. Test
(1) Make sure that there is no amber pressure value and no amber half box on the DOOR/OXY page.
5. Close-up(1) Make sure that there is no amber pressure value and no amber half box on the DOOR/OXY page.
Subtask 35-10-00-860-059-A
A. Put the aircraft back to its initial configuration.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
AMM 31-60-00-860-002.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
AMM 31-60-00-860-002.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.