W DOC AIRBUS | TSM A320F

Crew Oxygen Mask Dirty


TASK 35-10-00-810-807-A
Crew Oxygen Mask Dirty


1. Possible Causes
  • MASK-FULL FACE/Q.D. OXY, CAPT [5759HM]
  • MASK-FULL FACE/Q.D. OXY, F/O [5758HM]
  • MASK-FULL FACE/Q.D. OXY, 3RD OCCPNT [5757HM]
  • MASK-FULL FACE/Q.D. OXY, 4TH OCCPNT [5760HM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 35-12-41-100-001
Cleaning of Oxygen Masks
3. Fault Confirmation
Subtask 35-10-00-860-052-A
A. Job Set Up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
     (b) Make sure that this(these) circuit breaker(s) is(are) closed:
1HT.
     (c) On the panel 21VU push the OXYGEN/CREW SUPPLY pushbutton switch (the OFF legend goes off).
Subtask 35-10-00-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUOXYGEN/CREW/OXY/SPLY1HTHA01
Subtask 35-10-00-700-053-A
C. Test
   (1) Remove the oxygen mask from the flight crew oxygen box.
   (2) Make sure that the mask is dirty.
4. Fault Isolation
Subtask 35-10-00-810-056-B
A. If during the test:
   (1) The Captain Oxygen mask is dirty:
   (2) The First Officer mask is dirty:
   (3) The Third Occupant oxygen mask is dirty:
   (4) The Fourth Occupant oxygen mask is dirty:
5. Close-up
Subtask 35-10-00-860-056-A
A. Put the aircraft back to its initial configuration.
   (1) After you have examined the last oxygen mask, release the OXYGEN/CREW SUPPLY pushbutton switch (the OFF legend comes on).
   (2) De-energize the aircraft electrical circuits
[Rev.8 from Aug 2018] 2026.04.04 04:33:35 UTC