PRESS TO TEST AND RESET Button Inoperative
TASK 35-10-00-810-805-A
PRESS TO TEST AND RESET Button Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 35-10-00-710-055-A
Subtask 35-10-00-810-054-B
[Rev.8 from Aug 2018]
2026.04.04 04:33:35 UTC
PRESS TO TEST AND RESET Button Inoperative
1. Possible Causes
- STOWAGE BOX-OXY MASK, CAPT [10RN1]
- STOWAGE BOX-OXY MASK, F/O [10RN2]
- STOWAGE BOX-OXY MASK, 3RD OCCPNT [10RN3]
- STOWAGE BOX-OXY MASK, 4TH OCCPNT [5774HM]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 35-12-41-000-001 | Removal of the Oxygen-Mask Stowage-Box |
| AMM 35-12-41-400-001 | Installation of the Oxygen-Mask Stowage-Box |
| AMM 35-12-41-710-001 | Operational Test of the Full Face/Quick Donning Oxygen Masks |
Subtask 35-10-00-710-055-A
A. Test
(1) Do the operational test of the full-face/quick-donning oxygen mask AMM 35-12-41-710-001.
4. Fault Isolation(1) Do the operational test of the full-face/quick-donning oxygen mask AMM 35-12-41-710-001.
Subtask 35-10-00-810-054-B
A. If during the operational test
(1) The Captain PRESS TO TEST and RESET button is inoperative:
Subtask 35-10-00-710-056-A (1) The Captain PRESS TO TEST and RESET button is inoperative:
- replace the STOWAGE BOX-OXY MASK, CAPT [10RN1] AMM 35-12-41-000-001 and AMM 35-12-41-400-001.
- replace the STOWAGE BOX-OXY MASK, F/O [10RN2] AMM 35-12-41-000-001 and AMM 35-12-41-400-001.
- replace the STOWAGE BOX-OXY MASK, 3RD OCCPNT [10RN3] AMM 35-12-41-000-001 and AMM 35-12-41-400-001.
- replace the STOWAGE BOX-OXY MASK, 4TH OCCPNT [5774HM] AMM 35-12-41-000-001 and AMM 35-12-41-400-001.
B. Do the test given in Para. 3.A.