REGUL LO PR with Oxygen Consumption without the Use of the Oxygen Mask
TASK 35-10-00-810-802-A
REGUL LO PR with Oxygen Consumption without the Use of the Oxygen Mask
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 35-10-00-700-050-A 4. Fault Isolation
Subtask 35-10-00-810-051-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:35 UTC
REGUL LO PR with Oxygen Consumption without the Use of the Oxygen Mask
1. Possible Causes
- STOWAGE BOX-OXY MASK, CAPT [10RN1]
- STOWAGE BOX-OXY MASK, F/O [10RN2]
- STOWAGE BOX-OXY MASK, 3RD OCCPNT [10RN3]
- STOWAGE BOX-OXY MASK, 4TH OCCPNT [5774HM]
- HOSE-STOWAGE BOX [5764HM]
- HOSE-STOWAGE BOX [5765HM]
- HOSE-STOWAGE BOX [5766HM]
- HOSE-STOWAGE BOX [5768HM]
- MANIFOLD-OXY DISTRIBUTION [5753HM]
- TEST PORT-OXY SYS [5755HM]
- HOSE-OXY SPLY [5763HM]
- XMTR/PRESS REG-OXY [4HT]
- SOL VALVE-LP OXY SPLY [3HT]
- PRESS SW-OXYGEN LO PR [4WV]
- MANIFOLD DISTRIBUTION [5753HM1]
- PORT.ASSY TEST [5755HM1]
- 5762HM1
- 5763HM1
- LP SOLENOID SUPPLY VALVE [3HT1]
- PRESSURE SWITCH [4WV1]
- MANIFOLD DISTRIBUTION [5753HM2]
- PORT.ASSY TEST [5755HM2]
- PRESS.TRANSM.REGULATO [4HT2]
- 5762HM2
- 5763HM2
- LP SOLENOID SUPPLY VALVE [3HT2]
- PRESSURE SWITCH [4WV2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 35-10-00-790-001 | Leak Test of the Crew LP Oxygen-System |
| AMM 35-12-41-000-001 | Removal of the Oxygen-Mask Stowage-Box |
| AMM 35-12-41-400-001 | Installation of the Oxygen-Mask Stowage-Box |
| AMM 35-13-14-000-001 | Removal of the Low-Pressure Oxygen Pressure-Switch |
| AMM 35-13-14-000-802 | Removal of the Low-Pressure Oxygen Pressure-Switches |
| AMM 35-13-14-400-001 | Installation of the Low-Pressure Oxygen Pressure-Switch |
| AMM 35-13-14-400-802 | Installation of the Low-Pressure Oxygen Pressure-Switches |
| AMM 35-13-15-000-001 | Removal of the Oxygen Pressure Regulator/Transmitter |
| AMM 35-13-15-000-802 | Removal of the Oxygen Pressure Regulator/Transmitters |
| AMM 35-13-15-400-001 | Installation of the Oxygen Pressure Regulator/Transmitter |
| AMM 35-13-15-400-802 | Installation of the Oxygen Pressure Regulator/Transmitters |
| AMM 35-13-41-000-802 | Removal of the Oxygen-System Test Ports |
| AMM 35-13-41-400-802 | Installation of the Oxygen-System Test Ports |
| AMM 35-13-51-000-001 | Removal of the Low-Pressure Oxygen-Supply Solenoid-Valve |
| AMM 35-13-51-000-802 | Removal of the Low-Pressure Oxygen-Supply Solenoid-Valves |
| AMM 35-13-51-400-001 | Installation of the Low-Pressure Oxygen-Supply Solenoid-Valve |
| AMM 35-13-51-400-802 | Installation of the Low-Pressure Oxygen-Supply Solenoid-Valves |
Subtask 35-10-00-700-050-A 4. Fault Isolation
Subtask 35-10-00-810-051-B ** ON A/C NOT FOR ALL
A. If the pressure decreases during the leakage test
Subtask 35-10-00-810-051-C ** ON A/C NOT FOR ALL - replace the defective component: STOWAGE BOX-OXY MASK, CAPT [10RN1] or STOWAGE BOX-OXY MASK, F/O [10RN2] or STOWAGE BOX-OXY MASK, 3RD OCCPNT [10RN3] or STOWAGE BOX-OXY MASK, 4TH OCCPNT [5774HM] AMM 35-12-41-000-001 and AMM 35-12-41-400-001 or HOSE-STOWAGE BOX [5764HM] or HOSE-STOWAGE BOX [5765HM] or HOSE-STOWAGE BOX [5766HM] or HOSE-STOWAGE BOX [5768HM] or MANIFOLD-OXY DISTRIBUTION [5753HM] or TEST PORT-OXY SYS [5755HM] or HOSE-OXY SPLY [5763HM] or XMTR/PRESS REG-OXY [4HT]
AMM 35-13-15-000-001 and AMM 35-13-15-400-001 or SOL VALVE-LP OXY SPLY [3HT] AMM 35-13-51-000-001 and AMM 35-13-51-400-001 or PRESS SW-OXYGEN LO PR [4WV] AMM 35-13-14-000-001 and AMM 35-13-14-400-001.
A. If the pressure of the Captain LP oxygen-system decreases during the leak test:
(1) Replace the defective component:
Subtask 35-10-00-810-087-A ** ON A/C NOT FOR ALL (1) Replace the defective component:
- STOWAGE BOX-OXY MASK, CAPT [10RN1] or STOWAGE BOX-OXY MASK, 3RD OCCPNT [10RN3] AMM 35-12-41-000-001 and AMM 35-12-41-400-001, or
- HOSE-STOWAGE BOX [5764HM] or HOSE-STOWAGE BOX [5766HM] , or
- MANIFOLD DISTRIBUTION [5753HM1] , or
- PORT.ASSY TEST [5755HM1] AMM 35-13-41-000-802 and AMM 35-13-41-400-802, or
- XMTR/PRESS REG-OXY [4HT] or its(their) flexible hose(s) 5762HM1 or 5763HM1 AMM 35-13-15-000-802 and AMM 35-13-15-400-802, or
- LP SOLENOID SUPPLY VALVE [3HT1] AMM 35-13-51-000-802 and AMM 35-13-51-400-802, or
- PRESSURE SWITCH [4WV1] AMM 35-13-14-000-802 and AMM 35-13-14-400-802.
B. If the pressure of the First-Officer LP oxygen-system decreases during the leak test:
(1) Replace the defective component:
Subtask 35-10-00-700-051-A (1) Replace the defective component:
- STOWAGE BOX-OXY MASK, F/O [10RN2] or STOWAGE BOX-OXY MASK, 4TH OCCPNT [5774HM] AMM 35-12-41-000-001 and AMM 35-12-41-400-001, or
- HOSE-STOWAGE BOX [5765HM] or HOSE-STOWAGE BOX [5768HM] , or
- MANIFOLD DISTRIBUTION [5753HM2] , or
- PORT.ASSY TEST [5755HM2] AMM 35-13-41-000-802 and AMM 35-13-41-400-802, or
- PRESS.TRANSM.REGULATO [4HT2] or its(their) flexible hose(s) 5762HM2 or 5763HM2 AMM 35-13-15-000-802 and AMM 35-13-15-400-802, or
- LP SOLENOID SUPPLY VALVE [3HT2] AMM 35-13-51-000-802 and AMM 35-13-51-400-802, or
- PRESSURE SWITCH [4WV2] AMM 35-13-14-000-802 and AMM 35-13-14-400-802.
C. Do the test given in Para. 3.A.