W DOC AIRBUS | TSM A320F

REGUL LO PR with Oxygen Consumption without the Use of the Oxygen Mask


TASK 35-10-00-810-802-A
REGUL LO PR with Oxygen Consumption without the Use of the Oxygen Mask


1. Possible Causes
  • STOWAGE BOX-OXY MASK, CAPT [10RN1]
  • STOWAGE BOX-OXY MASK, F/O [10RN2]
  • STOWAGE BOX-OXY MASK, 3RD OCCPNT [10RN3]
  • STOWAGE BOX-OXY MASK, 4TH OCCPNT [5774HM]
  • HOSE-STOWAGE BOX [5764HM]
  • HOSE-STOWAGE BOX [5765HM]
  • HOSE-STOWAGE BOX [5766HM]
  • HOSE-STOWAGE BOX [5768HM]
  • MANIFOLD-OXY DISTRIBUTION [5753HM]
  • TEST PORT-OXY SYS [5755HM]
  • HOSE-OXY SPLY [5763HM]
  • XMTR/PRESS REG-OXY [4HT]
  • SOL VALVE-LP OXY SPLY [3HT]
  • PRESS SW-OXYGEN LO PR [4WV]
  • MANIFOLD DISTRIBUTION [5753HM1]
  • PORT.ASSY TEST [5755HM1]
  • 5762HM1
  • 5763HM1
  • LP SOLENOID SUPPLY VALVE [3HT1]
  • PRESSURE SWITCH [4WV1]
  • MANIFOLD DISTRIBUTION [5753HM2]
  • PORT.ASSY TEST [5755HM2]
  • PRESS.TRANSM.REGULATO [4HT2]
  • 5762HM2
  • 5763HM2
  • LP SOLENOID SUPPLY VALVE [3HT2]
  • PRESSURE SWITCH [4WV2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 35-10-00-790-001
Leak Test of the Crew LP Oxygen-System
AMM 35-12-41-000-001
Removal of the Oxygen-Mask Stowage-Box
AMM 35-12-41-400-001
Installation of the Oxygen-Mask Stowage-Box
AMM 35-13-14-000-001
Removal of the Low-Pressure Oxygen Pressure-Switch
AMM 35-13-14-000-802
Removal of the Low-Pressure Oxygen Pressure-Switches
AMM 35-13-14-400-001
Installation of the Low-Pressure Oxygen Pressure-Switch
AMM 35-13-14-400-802
Installation of the Low-Pressure Oxygen Pressure-Switches
AMM 35-13-15-000-001
Removal of the Oxygen Pressure Regulator/Transmitter
AMM 35-13-15-000-802
Removal of the Oxygen Pressure Regulator/Transmitters
AMM 35-13-15-400-001
Installation of the Oxygen Pressure Regulator/Transmitter
AMM 35-13-15-400-802
Installation of the Oxygen Pressure Regulator/Transmitters
AMM 35-13-41-000-802
Removal of the Oxygen-System Test Ports
AMM 35-13-41-400-802
Installation of the Oxygen-System Test Ports
AMM 35-13-51-000-001
Removal of the Low-Pressure Oxygen-Supply Solenoid-Valve
AMM 35-13-51-000-802
Removal of the Low-Pressure Oxygen-Supply Solenoid-Valves
AMM 35-13-51-400-001
Installation of the Low-Pressure Oxygen-Supply Solenoid-Valve
AMM 35-13-51-400-802
Installation of the Low-Pressure Oxygen-Supply Solenoid-Valves
3. Fault Confirmation
Subtask 35-10-00-700-050-A
A. Test
   (1) Do the leak test of the crew LP oxygen-system AMM 35-10-00-790-001.
4. Fault Isolation
Subtask 35-10-00-810-051-B ** ON A/C NOT FOR ALL
A. If the pressure decreases during the leakage test
Subtask 35-10-00-810-051-C ** ON A/C NOT FOR ALL
A. If the pressure of the Captain LP oxygen-system decreases during the leak test:
   (1) Replace the defective component:
Subtask 35-10-00-810-087-A ** ON A/C NOT FOR ALL
B. If the pressure of the First-Officer LP oxygen-system decreases during the leak test:
   (1) Replace the defective component:
Subtask 35-10-00-700-051-A
C. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:33:35 UTC