Loss of the Heading Data on the VOR/ADF/DME RMI


TASK 34-57-00-810-815-A
Loss of the Heading Data on the VOR/ADF/DME RMI


1. Possible Causes
  • SEL SW-ATT HDG [13FP]
  • RELAY-HDG SOURCE SEL (19FN)
  • wiring of the HDG SOURCE SEL relay (19FN)
  • RMI-VOR/ADF/DME [21FN]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-14-00-740-001
Interface Test of the IR
ASM 345701
AMM 34-57-22-000-002
Removal of the VOR/ADF/DME RMI
AMM 34-57-22-400-002
Installation of the VOR/ADF/DME RMI
3. Fault Confirmation
Subtask 34-57-00-740-066-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the Interface test of the IR AMM 34-14-00-740-001.
4. Fault Isolation
Subtask 34-57-00-810-067-B ** ON A/C NOT FOR ALL
A. If during the test, with the ATT HDG selector switch at CAPT 3, the HDG data do not come into view on the VOR/ADF/DME RMI (21FN):
  • do a check for a maintenance message in the BITE test of the IR system.
   (1) If the BITE test gives a maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
   (2) If the BITE test does not give a maintenance message:
  • replace the SEL SW-ATT HDG [13FP]
     (a) If the fault continues:
  • replace the RELAY-HDG SOURCE SEL (19FN).
       1 If the fault continues:
  • do a check of the wiring of the HDG SOURCE SEL relay (19FN):
    . pins A/A and A/Z to the ground points
    . pin A/X to the ATT HDG selector switch (13FP): pin A/1
    . pin A/2 to VOR/ADF/DME RMI (21FN): pin A/16.
    ASM 345701.
         a If there is no continuity:
  • repair the above wiring.
         b If there is continuity:
Subtask 34-57-00-740-067-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.