W DOC AIRBUS | TSM A320F

Loss of the ADF2 Data on the RMI


TASK 34-57-00-810-807-A
Loss of the ADF2 Data on the RMI


1. Possible Causes
  • RECEIVER-ADF, 2 [2RP2]
  • wiring of the BEARING OUTPUT BUS 2 bus from the ADF2 receiver (2RP2) to the first terminal block
  • RMI-VOR/ADF/DME [21FN]
  • wiring of the ADF2 bus from the VOR/ADF/DME RMI (21FN) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 34-53-00-810-822-A
Loss of the ADF 2 Data on the ND
AMM 34-53-00-710-002
Operational Test of the ADF
AMM 34-53-00-740-003
BITE Test of the ADF
AMM 34-53-31-000-002
Removal of the ADF Receiver
AMM 34-53-31-400-002
Installation of the ADF Receiver
ASM 345701
AMM 34-57-22-000-002
Removal of the VOR/ADF/DME RMI
AMM 34-57-22-400-002
Installation of the VOR/ADF/DME RMI
3. Fault Confirmation
Subtask 34-57-00-710-052-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the ADF AMM 34-53-00-710-002.
4. Fault Isolation
Subtask 34-57-00-810-059-C ** ON A/C NOT FOR ALL
A. If during the test, on the RMI, the ADF2 pointer does not indicate the station set:
  • make sure that the red flag comes into view on the RMI and on the ND.
   (1) If no flag comes into view on the RMI and on the ND:
   (2) If the flag comes into view on the RMI and on the ND:
     (a) If the BITE test gives a maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
     (b) If the BITE test does not gives a maintenance message:
       1 If the fault continues:
  • do a check and repair the wiring of the BEARING OUTPUT BUS 2 bus from the ADF2 receiver (2RP2) to the first terminal block ASM 345701.
   (3) If the flag comes into view only on the RMI:
     (a) If the fault continues:
  • do a check and repair the wiring of the ADF2 bus from the VOR/ADF/DME RMI (21FN) to the first terminal block ASM 345701.
Subtask 34-57-00-710-053-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.