Loss of the VOR2 Data on the RMI
TASK 34-57-00-810-805-A
Loss of the VOR2 Data on the RMI
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-57-00-720-052-A ** ON A/C NOT FOR ALL
Subtask 34-57-00-810-057-C ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:33 UTC
Loss of the VOR2 Data on the RMI
1. Possible Causes
- RECEIVER-VOR/MKR, 2 [3RS2]
wiring of the OMNI BEARING OUTPUT 2 bus from the VOR/MARKER 2 receiver (3RS2) to the first terminal block - RMI-VOR/ADF/DME [21FN]
wiring of the VOR2 bus from the VOR/ADF/DME RMI (21FN) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 34-55-00-810-814-A | Loss of the VOR 2 Data on the ND |
| AMM 34-55-00-720-001 | Functional Test of the VOR/MKR |
| AMM 34-55-00-740-002 | BITE Test of the VOR/MKR |
| AMM 34-55-31-000-001 | Removal of the VOR/MKR Receiver |
| AMM 34-55-31-400-001 | Installation of the VOR/MKR Receiver |
| ASM 345701 | |
| AMM 34-57-22-000-002 | Removal of the VOR/ADF/DME RMI |
| AMM 34-57-22-400-002 | Installation of the VOR/ADF/DME RMI |
Subtask 34-57-00-720-052-A ** ON A/C NOT FOR ALL
A. Test
Do the functional test of the VOR/MKR (test of the VOR reception and identification) AMM 34-55-00-720-001.
4. Fault IsolationDo the functional test of the VOR/MKR (test of the VOR reception and identification) AMM 34-55-00-720-001.
Subtask 34-57-00-810-057-C ** ON A/C NOT FOR ALL
A. If during the test, on the RMI, the VOR1 pointer does not move:
Subtask 34-57-00-720-053-A ** ON A/C NOT FOR ALL - make sure that the red flag comes into view on the RMI and on the ND.
- refer to the trouble shooting procedure (Ref. TSM TASK 34-55-00-810-814).
- do the BITE test of the VOR/MKR AMM 34-55-00-740-002.
- Do the trouble shooting procedure related to the maintenance message.
- replace the RECEIVER-VOR/MKR, 2 [3RS2] AMM 34-55-31-000-001 and AMM 34-55-31-400-001.
- do a check and repair the
wiring of the OMNI BEARING OUTPUT 2 bus from the VOR/MARKER 2 receiver (3RS2) to the first terminal block ASM 345701.
- replace the RMI-VOR/ADF/DME [21FN] AMM 34-57-22-000-002 and AMM 34-57-22-400-002.
- do a check and repair the
wiring of the VOR2 bus from the VOR/ADF/DME RMI (21FN) to the first terminal block ASM 345701.
B. Do the test given in Para. 3.