W DOC AIRBUS | TSM A320F

Erroneous VOR1 (VOR2) Bearing Indications


TASK 34-55-00-810-838-A
Erroneous VOR1 (VOR2) Bearing Indications


1. Possible Causes
  • the connectors 53VC or (40VC)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2044310
AMM 34-55-00-720-001
Functional Test of the VOR/MKR
AWM 345503
AWM 345504
3. Fault Confirmation
Subtask 34-55-00-740-098-A
A. Do the Functional Test of the VOR/MKR
AMM 34-55-00-720-001.
4. Fault Isolation
Subtask 34-55-00-810-095-A
A. If the operational test shows an erroneous indications or fluctuations:
-Do a check and repair if necessary the connectors 53VC or (40VC).
AWM 345503 or
AWM 345504
ESPM 2044310
Subtask 34-55-00-740-099-A
B. Do the test given in Para. 3