Erroneous VOR1 (VOR2) Bearing Indications
TASK 34-55-00-810-838-A
Erroneous VOR1 (VOR2) Bearing Indications
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-55-00-740-098-A 4. Fault Isolation
Subtask 34-55-00-810-095-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:32 UTC
Erroneous VOR1 (VOR2) Bearing Indications
1. Possible Causes
the connectors 53VC or (40VC)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2044310 | |
| AMM 34-55-00-720-001 | Functional Test of the VOR/MKR |
| AWM 345503 | |
| AWM 345504 |
Subtask 34-55-00-740-098-A 4. Fault Isolation
Subtask 34-55-00-810-095-A
A. If the operational test shows an erroneous indications or fluctuations:
-Do a check and repair if necessarythe connectors 53VC or (40VC) .
AWM 345503 or
AWM 345504
ESPM 2044310
Subtask 34-55-00-740-099-A -Do a check and repair if necessary
AWM 345503 or
AWM 345504
ESPM 2044310
B. Do the test given in Para. 3