W DOC AIRBUS | TSM A320F

Loss of the VOR1 Interface with the DMC1


TASK 34-55-00-810-837-A
Loss of the VOR1 Interface with the DMC1


1. Possible Causes
  • DMC-1 [1WT1]
  • wiring between the DMC1 and the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-004
EIS System Test
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
ASM 345501
3. Fault Confirmation
Subtask 34-55-00-740-096-A
A. Test
Do the BITE test of the VOR/MARKER (system 1) AMM 34-55-00-740-002.
4. Fault Isolation
Subtask 34-55-00-810-094-A
A. If the test gives the maintenance message DMC1/2 (1WT1/2)/DDRMI (1FN)/VOR1 (3RS1):
   (1) If the test gives a maintenance message related to a DMC1 fault:
   (2) If the test is OK:
  • remove the DMC1
  • do a check and repair the wiring between the DMC1 and the first terminal block : for pins AA/9C, 9D ASM 345501
  • install the DMC1.
Subtask 34-55-00-740-097-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:32 UTC