Loss of the VOR2 Interface with the DMC2
TASK 34-55-00-810-834-A
Loss of the VOR2 Interface with the DMC2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-55-00-740-090-A 4. Fault Isolation
Subtask 34-55-00-810-091-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:32 UTC
Loss of the VOR2 Interface with the DMC2
1. Possible Causes
- DMC-2 [1WT2]
- wiring between the DMC2 and the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-004 | EIS System Test |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
| AMM 34-55-00-740-002 | BITE Test of the VOR/MKR |
| ASM 345501 |
Subtask 34-55-00-740-090-A 4. Fault Isolation
Subtask 34-55-00-810-091-A
A. If the test gives the maintenance message DMC2/1(1WT2/1)/DDRMI(1FN)/VOR2 (3RS2):
Subtask 34-55-00-740-091-A - do the SYSTEM TEST of the DMC2 AMM 31-60-00-740-004.
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- remove the DMC2
- do a check and repair the wiring between the DMC2 and the first terminal block : for pins AA/9G, 9H ASM 345501
- install the DMC2.
B. Do the test given in Para. 3.