Loss of the VOR2 Data
TASK 34-55-00-810-833-A
Loss of the VOR2 Data
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-55-00-740-088-A 4. Fault Isolation
Subtask 34-55-00-810-090-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:32 UTC
Loss of the VOR2 Data
1. Possible Causes
- RECEIVER-VOR/MKR, 2 [3RS2]
wiring between the VOR/MKR receiver 2 and the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-55-00-740-002 | BITE Test of the VOR/MKR |
| ASM 345501 | |
| AMM 34-55-31-000-001 | Removal of the VOR/MKR Receiver |
| AMM 34-55-31-400-001 | Installation of the VOR/MKR Receiver |
Subtask 34-55-00-740-088-A 4. Fault Isolation
Subtask 34-55-00-810-090-A
A. If the test gives the maintenance message DMC2/1 (1WT2/1)/DDRMI (1FN)/VOR2 (3RS2):
Subtask 34-55-00-740-089-A - swap the RECEIVER-VOR/MKR, 2 [3RS2] and the VOR/MKR receiver 1 AMM 34-55-31-000-001 and AMM 34-55-31-400-001.
- replace the VOR/MKR receiver that you installed on side 1.
- remove the VOR/MKR receiver 2
- do a check and repair the
wiring between the VOR/MKR receiver 2 and the first terminal block : for pins AB/13B, 13C ASM 345501 - install the VOR/MKR receiver 2.
B. Do the test given in Para. 3.