W DOC AIRBUS | TSM A320F

Loss of the VOR1 Display on the DDRMI


TASK 34-55-00-810-832-A
Loss of the VOR1 Display on the DDRMI


1. Possible Causes
  • RMI-VOR/DME [11FN]
  • wiring between the DDRMI and the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
ASM 345501
AMM 34-57-22-000-001
Removal of the VOR/DME RMI
AMM 34-57-22-400-001
Installation of the VOR/DME RMI
3. Fault Confirmation
Subtask 34-55-00-740-086-A ** ON A/C NOT FOR ALL
A. Test
Do the BITE test of the VOR/MARKER (system 1) AMM 34-55-00-740-002.
4. Fault Isolation
Subtask 34-55-00-810-089-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC1/2 (1WT1/2)/DDRMI (1FN)/VOR1(3RS1):
   (1) If the fault continues:
  • remove the DDRMI
  • do a check and repair the wiring between the DDRMI and the first terminal block : for pins A/<B, <C ASM 345501
  • install the DDRMI.
Subtask 34-55-00-740-087-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:32 UTC