W DOC AIRBUS | TSM A320F

Loss of the VOR1 Data


TASK 34-55-00-810-830-A
Loss of the VOR1 Data


1. Possible Causes
  • RECEIVER-VOR/MKR, 1 [3RS1]
  • wiring between the VOR/MKR receiver 1 and the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
ASM 345501
AMM 34-55-31-000-001
Removal of the VOR/MKR Receiver
AMM 34-55-31-400-001
Installation of the VOR/MKR Receiver
3. Fault Confirmation
Subtask 34-55-00-740-082-A
A. Test
Do the BITE test of the VOR/MARKER (system 1) AMM 34-55-00-740-002.
4. Fault Isolation
Subtask 34-55-00-810-087-A
A. If the test gives the maintenance message DMC1/2 (1WT1/2)/DDRMI (1FN)/VOR1 (3RS1):
   (1) If the fault stops:
  • replace the VOR/MKR receiver that you installed on side 2.
   (2) If the fault continues:
  • remove the VOR/MKR receiver 1
  • do a check and repair the wiring between the VOR/MKR receiver 1 and the first terminal block: for pins AB/13B, 13C ASM 345501
  • install the VOR/MKR receiver 1.
Subtask 34-55-00-740-083-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:32 UTC