W DOC AIRBUS | TSM A320F

Loss of the VOR 2 Tuning Data


TASK 34-55-00-810-824-A
Loss of the VOR 2 Tuning Data


1. Possible Causes
  • FMGC-2 [1CA2]
  • wiring of the FMGC OWN CB 1 bus from the FMGC 2 (1CA2) to the first terminal block
  • RMP-COM/NAV FREQ SEL, 2 [1RG2]
  • wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block
  • wiring of the NAV DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block
  • RECEIVER-VOR/MKR, 2 [3RS2]
  • wiring of the FREQ FUNCT DATA SOURCE bus from the VOR/MKR receiver 2 (3RS2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228602
ASM 231301
AMM 23-13-13-000-001
Removal of the Radio Management Panel (RMP)
AMM 23-13-13-400-001
Installation of the Radio Management Panel (RMP)
AMM 34-14-00-740-001
Interface Test of the IR
AMM 34-36-00-740-002
BITE Test of the ILS
ASM 343601
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
ASM 345501
AMM 34-55-31-000-001
Removal of the VOR/MKR Receiver
AMM 34-55-31-400-001
Installation of the VOR/MKR Receiver
3. Fault Confirmation
Subtask 34-55-00-740-080-A
A. Test
   (1) Do the BITE test of the VOR/MKR AMM 34-55-00-740-002.
4. Fault Isolation
Subtask 34-55-00-810-083-B
A. If the test gives the maintenance message FGMC2(1CA2)/RMP2(1RG2)/VOR2(3RS2):
  • on the center pedestal, on the RMP 2, push the NAV and the VOR pushbutton switches (the green LED on these pushbutton switches comes on)
  • do the BITE test of the VOR/MKR AMM 34-55-00-740-002.
   (1) If the test does not give the maintenance message FMGC2(1CA2)/RMP2(1RG2)/VOR2 (3RS2):
     (a) If the Interface test of the IR gives the maintenance message ADIRU1 : NO FMGC 2 DATA:
       1 If the fault continues:
  • do a check and repair the wiring of the FMGC OWN CB 1 bus from the FMGC 2 (1CA2) to the first terminal block ASM 228602.
     (b) If the Interface test of the IR does not give the maintenance message ADIRU1 : NO FMGC 2 DATA:
       1 If the fault continues:
  • do a check and repair the wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block ASM 231301.
   (2) If the test gives again the maintenance message FMGC2(1CA2)/RMP2(1RG2)/VOR2 (3RS2):
     (a) If the BITE test gives the maintenance message ILS2 : NO DATA FROM CONTROL SOURCE:
       1 If the fault continues:
  • do a check and repair the wiring of the NAV DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block ASM 343601 .
     (b) If the BITE test does not give the maintenance message ILS2 : NO DATA FROM CONTROL SOURCE:
       1 If the fault continues:
  • do a check and repair the wiring of the FREQ FUNCT DATA SOURCE bus from the VOR/MKR receiver 2 (3RS2) to the first terminal block ASM 345501.
Subtask 34-55-00-740-081-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:32 UTC