BITE Test of the VOR 2 Inoperative
TASK 34-55-00-810-822-A
BITE Test of the VOR 2 Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-55-00-740-076-A
Subtask 34-55-00-810-081-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:31 UTC
BITE Test of the VOR 2 Inoperative
1. Possible Causes
- RECEIVER-VOR/MKR, 2 [3RS2]
- LGCIU-2 [5GA2]
wiring of the GND/AIR LOGIC discrete from the VOR/MKR receiver 2 (3RS2) to the LGCIU 2 (5GA2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AMM 34-55-00-740-002 | BITE Test of the VOR/MKR |
| ASM 345501 | |
| AMM 34-55-31-000-001 | Removal of the VOR/MKR Receiver |
| AMM 34-55-31-400-001 | Installation of the VOR/MKR Receiver |
Subtask 34-55-00-740-076-A
A. Test
(1) Not applicable, the fault is evident.
4. Fault Isolation(1) Not applicable, the fault is evident.
Subtask 34-55-00-810-081-A
A. If the BITE test of the VOR 2 cannot be started on the MCDU:
Subtask 34-55-00-740-077-A - replace the RECEIVER-VOR/MKR, 2 [3RS2] AMM 34-55-31-000-001 and AMM 34-55-31-400-001.
- replace the LGCIU-2 [5GA2] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- do a check and repair the
wiring of the GND/AIR LOGIC discrete from the VOR/MKR receiver 2 (3RS2) to the LGCIU 2 (5GA2) ASM 345501.