W DOC AIRBUS | TSM A320F

Loss of the CFDIU Input Bus on the VOR 2


TASK 34-55-00-810-820-A
Loss of the CFDIU Input Bus on the VOR 2


1. Possible Causes
  • RECEIVER-VOR/MKR, 2 [3RS2]
  • wiring of the MAINTENANCE DATA INPUT bus from the VOR/MKR receiver 2 (3RS2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
ASM 345501
AMM 34-55-31-000-001
Removal of the VOR/MKR Receiver
AMM 34-55-31-400-001
Installation of the VOR/MKR Receiver
3. Fault Confirmation
Subtask 34-55-00-740-072-A
A. Test
   (1) Do the BITE test of the VOR/MKR AMM 34-55-00-740-002.
4. Fault Isolation
Subtask 34-55-00-810-079-B
A. If the test gives the maintenance message CFDIU(1TW)/VOR2(3RS2):
   (1) If the fault continues:
  • do a check and repair the wiring of the MAINTENANCE DATA INPUT bus from the VOR/MKR receiver 2 (3RS2) to the first terminal block ASM 345501.
Subtask 34-55-00-740-073-A
B. Do the test given in Para. 3.