Loss of the CFDIU Input Bus on the VOR 1
TASK 34-55-00-810-819-A
Loss of the CFDIU Input Bus on the VOR 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-55-00-740-070-A 4. Fault Isolation
Subtask 34-55-00-810-078-B
[Rev.8 from Aug 2018]
2026.04.04 04:33:31 UTC
Loss of the CFDIU Input Bus on the VOR 1
1. Possible Causes
- RECEIVER-VOR/MKR, 1 [3RS1]
wiring of the MAINTENANCE DATA INPUT bus from the VOR/MKR receiver 1 (3RS1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-55-00-740-002 | BITE Test of the VOR/MKR |
| ASM 345501 | |
| AMM 34-55-31-000-001 | Removal of the VOR/MKR Receiver |
| AMM 34-55-31-400-001 | Installation of the VOR/MKR Receiver |
Subtask 34-55-00-740-070-A 4. Fault Isolation
Subtask 34-55-00-810-078-B
A. If the test gives the maintenance message CFDIU(1TW)/VOR1(3RS1):
Subtask 34-55-00-740-071-A - replace the RECEIVER-VOR/MKR, 1 [3RS1] AMM 34-55-31-000-001 and AMM 34-55-31-400-001.
- do a check and repair the
wiring of the MAINTENANCE DATA INPUT bus from the VOR/MKR receiver 1 (3RS1) to the first terminal block ASM 345501.
B. Do the test given in Para. 3.