VOR 2 System Inoperative


TASK 34-55-00-810-813-A
VOR 2 System Inoperative


1. Possible Causes
  • RECEIVER-VOR/MKR, 2 [3RS2]
  • wiring of the OMNI BEARING OUTPUT 2 bus from the VOR/MKR receiver 2 (3RS2) to the first terminal block
  • DMC-1 [1WT1]
  • wiring of the VOR 2 INPUT bus from the DMC 1 (1WT1) to the first terminal block
  • DMC-3 [1WT3]
  • wiring of the VOR 2 INPUT bus from the DMC 3 (1WT3) to the first terminal block
  • DMC-2 [1WT2]
  • wiring of the VOR 2 INPUT bus from the DMC 2 (1WT2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
AMM 34-55-00-720-001
Functional Test of the VOR/MKR
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
ASM 345501
AMM 34-55-31-000-001
Removal of the VOR/MKR Receiver
AMM 34-55-31-400-001
Installation of the VOR/MKR Receiver
3. Fault Confirmation
Subtask 34-55-00-720-054-A
A. Test
Do the functional test of the VOR/MKR (Test of the VOR reception and identification) AMM 34-55-00-720-001.
4. Fault Isolation
Subtask 34-55-00-810-068-A
A. If on the two NDs:
. the VOR 2 data do not come into view
. the red flag is shown:
- do the BITE test of the VOR/MKR AMM 34-55-00-740-002.
   (1) If the BITE test gives a maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
   (2) If the BITE test does not give a maintenance message:
     (a) If the fault continues:
  • do a check and repair the wiring of the OMNI BEARING OUTPUT 2 bus from the VOR/MKR receiver 2 (3RS2) to the first terminal block ASM 345501.
Subtask 34-55-00-810-069-A
B. If on the CAPT ND only:
. the VOR 2 data do not come into view
. the red flag is shown:
- make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at CAPT 3:
   (1) If no:
     (a) If the fault continues:
  • do a check and repair the wiring of the VOR 2 INPUT bus from the DMC 1 (1WT1) to the first terminal block ASM 345501.
   (2) If yes:
     (a) If the fault continues:
  • do a check and repair the wiring of the VOR 2 INPUT bus from the DMC 3 (1WT3) to the first terminal block ASM 345501.
Subtask 34-55-00-810-070-A
C. If on the F/O ND only:
. the VOR 2 data do not come into view
. the red flag is shown:
  • make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at F/O 3:
   (1) If no:
     (a) If the fault continues:
  • do a check and repair the wiring of the VOR 2 INPUT bus from the DMC 2 (1WT2) to the first terminal block ASM 345501.
   (2) If yes:
     (a) If the fault continues:
  • do a check and repair the wiring of the VOR 2 INPUT bus from the DMC 3 (1WT3) to the first terminal block ASM 345501.
Subtask 34-55-00-720-055-A
D. Do the tet given in Para. 3.