VOR 1 System Inoperative
TASK 34-55-00-810-811-A
VOR 1 System Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-55-00-720-052-A
Subtask 34-55-00-810-065-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:30 UTC
VOR 1 System Inoperative
1. Possible Causes
- RECEIVER-VOR/MKR, 1 [3RS1]
wiring of the OMNI BEARING AND SIGNAL MKR OUTPUT 2 bus from the VOR/MKR receiver 1 (3RS1) to the first terminal block - DMC-1 [1WT1]
wiring of the VOR 1/MKR INPUT bus from the DMC 1 (1WT1) to the first terminal block - DMC-3 [1WT3]
wiring of the VOR 1/MKR INPUT bus from the DMC 3 (1WT3) to the first terminal block - DMC-2 [1WT2]
wiring of the VOR 1/MKR INPUT bus from the DMC 2 (1WT2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
| AMM 34-55-00-720-001 | Functional Test of the VOR/MKR |
| AMM 34-55-00-740-002 | BITE Test of the VOR/MKR |
| ASM 345501 | |
| AMM 34-55-31-000-001 | Removal of the VOR/MKR Receiver |
| AMM 34-55-31-400-001 | Installation of the VOR/MKR Receiver |
Subtask 34-55-00-720-052-A
A. Test
Do the functional test of the VOR/MKR (Test of the VOR reception and identification) AMM 34-55-00-720-001.
4. Fault IsolationDo the functional test of the VOR/MKR (Test of the VOR reception and identification) AMM 34-55-00-720-001.
Subtask 34-55-00-810-065-A
A. If on the two NDs:
. the VOR 1 data do not come into view
. the red flag is shown:
- do the BITE test of the VOR/MKR AMM 34-55-00-740-002.
(1) If the BITE test gives a maintenance message:
Subtask 34-55-00-810-066-A . the VOR 1 data do not come into view
. the red flag is shown:
- do the BITE test of the VOR/MKR AMM 34-55-00-740-002.
(1) If the BITE test gives a maintenance message:
- Do the trouble shooting procedure related to the maintenance message.
- replace the RECEIVER-VOR/MKR, 1 [3RS1] AMM 34-55-31-000-001 and AMM 34-55-31-400-001.
- do a check and repair the
wiring of the OMNI BEARING AND SIGNAL MKR OUTPUT 2 bus from the VOR/MKR receiver 1 (3RS1) to the first terminal block ASM 345501.
B. If on the CAPT ND only:
. the VOR 1 data do not come into view
. the red flag is shown:
- make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at CAPT 3:
(1) If no:
Subtask 34-55-00-810-067-A . the VOR 1 data do not come into view
. the red flag is shown:
- make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at CAPT 3:
(1) If no:
- replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring of the VOR 1/MKR INPUT bus from the DMC 1 (1WT1) to the first terminal block ASM 345501.
- replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring of the VOR 1/MKR INPUT bus from the DMC 3 (1WT3) to the first terminal block ASM 345501.
C. If on the F/O ND only:
. the VOR 1 data do not come into view
. the red flag is shown:
- make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at F/O 3:
(1) If no:
Subtask 34-55-00-720-053-A . the VOR 1 data do not come into view
. the red flag is shown:
- make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at F/O 3:
(1) If no:
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring of the VOR 1/MKR INPUT bus from the DMC 2 (1WT2) to the first terminal block ASM 345501.
- replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring of the VOR 1/MKR INPUT bus from the DMC 3 (1WT3) to the first terminal block ASM 345501.
D. Do the test given in Para. 3.