Loss of the VOR 1 Data Bus Identified by the EIS 3
TASK 34-55-00-810-805-A
Loss of the VOR 1 Data Bus Identified by the EIS 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-55-00-865-052-A
Subtask 34-55-00-810-056-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:29 UTC
Loss of the VOR 1 Data Bus Identified by the EIS 3
1. Possible Causes
- RECEIVER-VOR/MKR, 1 [3RS1]
wiring of the OMNI BEARING AND SIGNAL MKR OUTPUT 2 bus from the VOR/MKR receiver 1 (3RS1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| ASM 345501 | |
| AMM 34-55-31-000-001 | Removal of the VOR/MKR Receiver |
| AMM 34-55-31-400-001 | Installation of the VOR/MKR Receiver |
Subtask 34-55-00-865-052-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 34-55-00-740-058-A ** ON A/C NOT FOR ALL Subtask 34-55-00-740-058-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | NAV/VOR/1 | 2RS1 | G13 |
Subtask 34-55-00-810-056-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 3 : NO VOR 1 DATA:
Subtask 34-55-00-810-056-B ** ON A/C NOT FOR ALL - replace the RECEIVER-VOR/MKR, 1 [3RS1] AMM 34-55-31-000-001 and AMM 34-55-31-400-001.
- do a check and repair the
wiring of the OMNI BEARING AND SIGNAL MKR OUTPUT 2 bus from the VOR/MKR receiver 1 (3RS1) to the first terminal block ASM 345501.
A. If the test gives the maintenance message DMC 3 : VOR1(3RS1)/DMC3(1WT3)
Subtask 34-55-00-740-059-A - replace the RECEIVER-VOR/MKR, 1 [3RS1] AMM 34-55-31-000-001 and AMM 34-55-31-400-001.
- do a check and repair the
wiring of the OMNI BEARING AND SIGNAL MKR OUTPUT 2 bus from the VOR/MKR receiver 1 (3RS1) to the first terminal block ASM 345501.
B. Do the test given in Para. 3.B.