Loss of the ADF2 Display on the F/O ND Only
TASK 34-53-00-810-830-A
Loss of the ADF2 Display on the F/O ND Only
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-53-00-740-098-A ** ON A/C NOT FOR ALL
Subtask 34-53-00-810-088-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:29 UTC
Loss of the ADF2 Display on the F/O ND Only
1. Possible Causes
- DMC-2 [1WT2]
- wiring between the DMC2 and the first terminal block
- DMC-3 [1WT3]
- wiring between the DMC3 and the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
| AMM 34-53-00-740-003 | BITE Test of the ADF |
| ASM 345301 |
Subtask 34-53-00-740-098-A ** ON A/C NOT FOR ALL
A. Test
Do the BITE test of the ADF (system 2) AMM 34-53-00-740-003.
4. Fault IsolationDo the BITE test of the ADF (system 2) AMM 34-53-00-740-003.
NOTE: Do the test with the EIS DMC selector switch (18WT) on the SWITCHING panel (8VU) at NORM then at F/O/3.
Subtask 34-53-00-810-088-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC1/2/3 (1WT1/2/3)/DDRMI (1FN)/ADF2 (2RP2) with the EIS DMC selector switch at NORM only:
Subtask 34-53-00-810-092-A ** ON A/C NOT FOR ALL - replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- remove the DMC2
- do a check and repair the wiring between the DMC2 and the first terminal block : for pins AA/8G, 8H of the DMC2 ASM 345301
- install the DMC2.
B. If the test gives the maintenance message DMC1/2/3 (1WT1/2/3)/DDRMI (1FN)/ADF2 (2RP2) with the EIS DMC selector switch at F/O/3 only:
Subtask 34-53-00-740-097-A ** ON A/C NOT FOR ALL - replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- remove the DMC3
- do a check and repair the wiring between the DMC3 and the first terminal block : for pins AA/8G, 8H of the DMC3 ASM 345301
- install the DMC3.
C. Do the test given in Para. 3.