W DOC AIRBUS | TSM A320F

Loss of the ADF2 Data


TASK 34-53-00-810-828-A
Loss of the ADF2 Data


1. Possible Causes
  • RECEIVER-ADF, 2 [2RP2]
  • wiring from the ADF receiver 2 to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-53-00-740-003
BITE Test of the ADF
ASM 345301
AMM 34-53-31-000-002
Removal of the ADF Receiver
AMM 34-53-31-400-002
Installation of the ADF Receiver
3. Fault Confirmation
Subtask 34-53-00-740-092-A ** ON A/C NOT FOR ALL
A. Test
Do the BITE test of the ADF (system 2) AMM 34-53-00-740-003.
4. Fault Isolation
Subtask 34-53-00-810-086-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC1/2/3 (1WT1/2/3)/DDRMI (1FN)/ADF2 (2RP2):
   (1) If the fault stops:
  • replace the ADF receiver that you installed on side 1.
   (2) If the fault continues:
  • remove the ADF receiver 2
  • do a check and repair the wiring from the ADF receiver 2 to the first terminal block : for pins AB/13B, 14B of the ADF receiver 2 ASM 345301
  • install the ADF receiver 2.
Subtask 34-53-00-740-093-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:28 UTC