W DOC AIRBUS | TSM A320F

ADF 2 System Inoperative


TASK 34-53-00-810-821-A
ADF 2 System Inoperative


1. Possible Causes
  • RECEIVER-ADF, 2 [2RP2]
  • wiring of the BEARING OUTPUT 2 bus from the ADF receiver 2 (2RP2) to the first terminal block
  • DMC-1 [1WT1]
  • wiring of the ADF 2 INPUT bus from the DMC 1 (1WT1) to the first terminal block
  • DMC-3 [1WT3]
  • wiring of the ADF 2 INPUT bus from the DMC 3 (1WT3) to the first terminal block
  • DMC-2 [1WT2]
  • wiring of the ADF 2 INPUT bus from the DMC 2 (1WT2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
AMM 34-53-00-710-002
Operational Test of the ADF
AMM 34-53-00-740-003
BITE Test of the ADF
ASM 345301
AMM 34-53-31-000-002
Removal of the ADF Receiver
AMM 34-53-31-400-002
Installation of the ADF Receiver
3. Fault Confirmation
Subtask 34-53-00-710-058-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the ADF AMM 34-53-00-710-002.
4. Fault Isolation
Subtask 34-53-00-810-074-A ** ON A/C NOT FOR ALL
A. If on the two NDs:
. the ADF 2 data do not come into view
. the red flag is shown:
   (1) If the BITE test gives a maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
   (2) If the BITE test does not give a maintenance message:
     (a) If the fault continues:
  • do a check and repair the wiring of the BEARING OUTPUT 2 bus from the ADF receiver 2 (2RP2) to the first terminal block ASM 345301.
Subtask 34-53-00-810-075-A ** ON A/C NOT FOR ALL
B. If on the CAPT ND only:
. the ADF 2 data do not come into view
. the red flag is shown:
  • make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at CAPT 3:
   (1) If no:
     (a) If the fault continues:
  • do a check and repair the wiring of the ADF 2 INPUT bus from the DMC 1 (1WT1) to the first terminal block ASM 345301.
   (2) If yes:
     (a) If the fault continues:
  • do a check and repair the wiring of the ADF 2 INPUT bus from the DMC 3 (1WT3) to the first terminal block ASM 345301.
Subtask 34-53-00-810-076-A ** ON A/C NOT FOR ALL
C. If on the F/O ND only:
. the ADF 2 data do not come into view
. the red flag is shown:
  • make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at F/O 3:
   (1) If no:
     (a) If the fault continues:
  • do a check and repair the wiring of the ADF 2 INPUT bus from the DMC 2 (1WT2) to the first terminal block ASM 345301.
   (2) If yes:
     (a) If the fault continues:
  • do a check and repair the wiring of the ADF 2 INPUT bus from the DMC 3 (1WT3) to the first terminal block ASM 345301.
Subtask 34-53-00-710-059-A ** ON A/C NOT FOR ALL
D. Do the test given in Para. 3.