ADF 1 System Inoperative
TASK 34-53-00-810-819-A
ADF 1 System Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-53-00-710-054-A 4. Fault Isolation
Subtask 34-53-00-810-070-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:27 UTC
ADF 1 System Inoperative
1. Possible Causes
- RECEIVER-ADF, 1 [2RP1]
wiring of the BEARING OUTPUT 2 bus from the ADF receiver 1 (2RP1) to the first terminal block - DMC-1 [1WT1]
wiring of the ADF 1 INPUT bus from the DMC 1 (1WT1) to the first terminal block - DMC-3 [1WT3]
wiring of the ADF 1 INPUT bus from the DMC 3 (1WT3) to the first terminal block - DMC-2 [1WT2]
wiring of the ADF 1 INPUT bus from the DMC 2 (1WT2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
| AMM 34-53-00-710-002 | Operational Test of the ADF |
| AMM 34-53-00-740-003 | BITE Test of the ADF |
| ASM 345301 | |
| AMM 34-53-31-000-002 | Removal of the ADF Receiver |
| AMM 34-53-31-400-002 | Installation of the ADF Receiver |
Subtask 34-53-00-710-054-A 4. Fault Isolation
Subtask 34-53-00-810-070-A
A. If on the two NDs:
. the ADF 1 data do not come into view
. the red flag is shown:
Subtask 34-53-00-810-071-A . the ADF 1 data do not come into view
. the red flag is shown:
- do the BITE test of the ADF AMM 34-53-00-740-003.
- Do the trouble shooting procedure related to the maintenance message.
- replace the RECEIVER-ADF, 1 [2RP1] AMM 34-53-31-000-002 and AMM 34-53-31-400-002.
- do a check and repair the
wiring of the BEARING OUTPUT 2 bus from the ADF receiver 1 (2RP1) to the first terminal block ASM 345301.
B. If on the CAPT ND only:
. the ADF 1 data do not come into view
. the red flag is shown:
Subtask 34-53-00-810-072-A . the ADF 1 data do not come into view
. the red flag is shown:
- make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at CAPT 3:
- replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring of the ADF 1 INPUT bus from the DMC 1 (1WT1) to the first terminal block ASM 345301.
- replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring of the ADF 1 INPUT bus from the DMC 3 (1WT3) to the first terminal block ASM 345301.
C. If on the F/O ND only:
. the ADF 1 data do not come into view
. the red flag is shown:
Subtask 34-53-00-710-055-A . the ADF 1 data do not come into view
. the red flag is shown:
- make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at F/O 3:
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring of the ADF 1 INPUT bus from the DMC 2 (1WT2) to the first terminal block ASM 345301.
- replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring of the ADF 1 INPUT bus from the DMC 3 (1WT3) to the first terminal block ASM 345301.
D. Do the test given in Para. 3.