W DOC AIRBUS | TSM A320F

BITE Test of the ADF 2 Inoperative


TASK 34-53-00-810-816-A
BITE Test of the ADF 2 Inoperative


1. Possible Causes
  • RECEIVER-ADF, 2 [2RP2]
  • LGCIU-2 [5GA2]
  • wiring of the GND/AIR LOGIC discrete from the ADF receiver 2 (2RP2) to the LGCIU 2 (5GA2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
AMM 34-53-00-740-003
BITE Test of the ADF
ASM 345301
AMM 34-53-31-000-002
Removal of the ADF Receiver
AMM 34-53-31-400-002
Installation of the ADF Receiver
3. Fault Confirmation
Subtask 34-53-00-740-080-A ** ON A/C NOT FOR ALL
A. Test
   (1) Not applicable, the fault is evident.
4. Fault Isolation
Subtask 34-53-00-810-067-A ** ON A/C NOT FOR ALL
A. If the BITE test of the ADF 2 cannot be started on the MCDU:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring of the GND/AIR LOGIC discrete from the ADF receiver 2 (2RP2) to the LGCIU 2 (5GA2) ASM 345301.
Subtask 34-53-00-740-081-A ** ON A/C NOT FOR ALL
B. Do the BITE test of the ADF AMM 34-53-00-740-003.
[Rev.8 from Aug 2018] 2026.04.04 04:33:27 UTC