BITE Test of the ADF 1 Inoperative
TASK 34-53-00-810-815-A
BITE Test of the ADF 1 Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-53-00-740-078-A
Subtask 34-53-00-810-066-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:27 UTC
BITE Test of the ADF 1 Inoperative
1. Possible Causes
- RECEIVER-ADF, 1 [2RP1]
- LGCIU-1 [5GA1]
wiring of the GND/AIR LOGIC discrete from the ADF receiver 1 (2RP1) to the LGCIU 1 (5GA1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AMM 34-53-00-740-003 | BITE Test of the ADF |
| ASM 345301 | |
| AMM 34-53-31-000-002 | Removal of the ADF Receiver |
| AMM 34-53-31-400-002 | Installation of the ADF Receiver |
Subtask 34-53-00-740-078-A
A. Test
(1) Not applicable, the fault is evident.
4. Fault Isolation(1) Not applicable, the fault is evident.
Subtask 34-53-00-810-066-A
A. If the BITE test of the ADF 1 cannot be started on the MCDU:
Subtask 34-53-00-740-079-A - replace the RECEIVER-ADF, 1 [2RP1] AMM 34-53-31-000-002 and AMM 34-53-31-400-002.
- replace the LGCIU-1 [5GA1] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- do a check and repair the
wiring of the GND/AIR LOGIC discrete from the ADF receiver 1 (2RP1) to the LGCIU 1 (5GA1) ASM 345301.