Loss of the CFDIU Input Bus on the ADF 2


TASK 34-53-00-810-814-A
Loss of the CFDIU Input Bus on the ADF 2


1. Possible Causes
  • RECEIVER-ADF, 2 [2RP2]
  • wiring of the MAINTENANCE DATA INPUT bus from the ADF receiver 2 (2RP2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-53-00-740-003
BITE Test of the ADF
ASM 345301
AMM 34-53-31-000-002
Removal of the ADF Receiver
AMM 34-53-31-400-002
Installation of the ADF Receiver
3. Fault Confirmation
Subtask 34-53-00-740-076-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the ADF AMM 34-53-00-740-003.
4. Fault Isolation
Subtask 34-53-00-810-065-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADF2 : NO DATA FROM CFDIU:
   (1) If the fault continues:
  • do a check and repair the wiring of the MAINTENANCE DATA INPUT bus from the ADF receiver 2 (2RP2) to the first terminal block ASM 345301.
Subtask 34-53-00-740-077-A ** ON A/C NOT FOR ALL