Loss of the CFDIU Input Bus on the ADF 2
TASK 34-53-00-810-814-A
Loss of the CFDIU Input Bus on the ADF 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-53-00-740-076-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-53-00-810-065-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:27 UTC
Loss of the CFDIU Input Bus on the ADF 2
1. Possible Causes
- RECEIVER-ADF, 2 [2RP2]
wiring of the MAINTENANCE DATA INPUT bus from the ADF receiver 2 (2RP2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-53-00-740-003 | BITE Test of the ADF |
| ASM 345301 | |
| AMM 34-53-31-000-002 | Removal of the ADF Receiver |
| AMM 34-53-31-400-002 | Installation of the ADF Receiver |
Subtask 34-53-00-740-076-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-53-00-810-065-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADF2 : NO DATA FROM CFDIU:
Subtask 34-53-00-740-077-A ** ON A/C NOT FOR ALL - replace the RECEIVER-ADF, 2 [2RP2] AMM 34-53-31-000-002 and AMM 34-53-31-400-002.
- do a check and repair the
wiring of the MAINTENANCE DATA INPUT bus from the ADF receiver 2 (2RP2) to the first terminal block ASM 345301.
B. Do the test given in Para. 3.