W DOC AIRBUS | TSM A320F

Loss of the ADF 2 Tuning Data


TASK 34-53-00-810-812-A
Loss of the ADF 2 Tuning Data


1. Possible Causes
  • FMGC-2 [1CA2]
  • wiring of the FMGC OWN CB 1 bus from the FMGC 2 (1CA2) to the first terminal block
  • RMP-COM/NAV FREQ SEL, 2 [1RG2]
  • wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block
  • wiring of the NAV FREQ DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 2 (1RG2) the first terminal block
  • RECEIVER-ADF, 2 [2RP2]
  • wiring of the FREQUENCY CONTROL PORT A bus from the ADF receiver 2 (2RP2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228602
ASM 231301
AMM 23-13-13-000-001
Removal of the Radio Management Panel (RMP)
AMM 23-13-13-400-001
Installation of the Radio Management Panel (RMP)
AMM 34-14-00-740-001
Interface Test of the IR
AMM 34-53-00-740-003
BITE Test of the ADF
ASM 345301
AMM 34-53-31-000-002
Removal of the ADF Receiver
AMM 34-53-31-400-002
Installation of the ADF Receiver
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
3. Fault Confirmation
Subtask 34-53-00-740-072-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the ADF AMM 34-53-00-740-003.
4. Fault Isolation
Subtask 34-53-00-810-063-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADF2 : NO DATA FROM CONTROL SOURCE:
  • on the center pedestal, on the RMP 2, push the NAV and the ADF pushbutton switches (the green LED on these pushbutton switches comes on).
  • do the BITE test of the ADF AMM 34-53-00-740-003.
   (1) If the test does not give the maintenance message ADF2 : NO DATA FROM CONTROL SOURCE:
     (a) If the Interface test of the IR (system 1) gives a maintenance message related to a FMGC2 failure:
       1 If the fault continues:
  • do a check and repair the wiring of the FMGC OWN CB 1 bus from the FMGC 2 (1CA2) to the first terminal block ASM 228602.
     (b) If the Interface test of the IR (system 1) does not give a maintenance message related to a FMGC2 failure:
       1 If the fault continues:
  • do a check and repair the wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block ASM 231301.
   (2) If the test gives again the maintenance message ADF2 : NO DATA FROM CONTROL SOURCE:
     (a) If the BITE test gives a maintenance message related to a RMP failure:
       1 If the fault continues:
  • do a check and repair the wiring of the NAV FREQ DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 2 (1RG2) the first terminal block ASM 345301.
     (b) If the BITE test does not give a maintenance message related to a RMP failure:
       1 If the fault continues:
  • do a check and repair the wiring of the FREQUENCY CONTROL PORT A bus from the ADF receiver 2 (2RP2) to the first terminal block ASM 345301.
Subtask 34-53-00-740-073-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:26 UTC