Loss of the ADF2 Data Bus Identified by the CFDS
TASK 34-53-00-810-810-A
Loss of the ADF2 Data Bus Identified by the CFDS
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-53-00-865-068-A ** ON A/C NOT FOR ALL
Subtask 34-53-00-810-061-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:26 UTC
Loss of the ADF2 Data Bus Identified by the CFDS
1. Possible Causes
- RECEIVER-ADF, 2 [2RP2]
wiring of the BEARING OUTPUT 2 bus from the ADF receiver 2 (2RP2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| ASM 345301 | |
| AMM 34-53-31-000-002 | Removal of the ADF Receiver |
| AMM 34-53-31-400-002 | Installation of the ADF Receiver |
Subtask 34-53-00-865-068-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 34-53-00-740-068-A ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/ADF/2 | 1RP2 | K02 |
Subtask 34-53-00-810-061-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO ADF2 DATA:
Subtask 34-53-00-740-069-A ** ON A/C NOT FOR ALL - replace the RECEIVER-ADF, 2 [2RP2] AMM 34-53-31-000-002 and AMM 34-53-31-400-002.
- do a check and repair the
wiring of the BEARING OUTPUT 2 bus from the ADF receiver 2 (2RP2) to the first terminal block ASM 345301.
B. Do the test given in Para. 3.B.